![akira AC-F30HG Service Manual Download Page 32](http://html1.mh-extra.com/html/akira/ac-f30hg/ac-f30hg_service-manual_2885925032.webp)
32
Model No: AC-F30HG
Version 1.0
d. Fanning mode:
The indoor unit fan motor runs in the set speed:
The range of set temperature 16
o
C ~ 30
o
C.
e. Auto mode:
It runs, according the Tin.
If T
in
>26
o
C, cooling mode act, the T
set
is 26
o
C automatically;
If 20
o
C Tin 26
o
C, drying mode act, the T
set
is 24
o
C automatically;
If T
in
<20
o
C, heating mode act, the Tset is 20 automatically till Tin 24 .
If the unit is cooling only, when Tin<20 , fanning mode act, the Tset is 20 automatically till
Tin 24 .
Once the each mode act, it will be in 30sec to change to the auto mode according. the Tin.
5. Timer and sleep mode:
1. Sleep mode:
If it is cooling or drying, in 1hour of the beginning, the T
set
will be increased 1
o
C automatically,
and it will be increased 1
o
C automatically after 2hour from the beginning, then the unit runs in
this temperature.
If it is heating, in 1hour of the beginning, the T
set
will be decreased 1
o
C automatically, and it will
be decreased 1 automatically after 2hour from the beginning 2, then the unit runs in this
temperature.
There is no sleep mode when fanning and auto mode act.
2. Timer for turn on:
The unit is stop when the timer for turn on is acted, when it is time to turn on, the controller will
act in the set mode. The distance of setting twice is 0.5hour, and the range time is 0.5~24 hour.
3. Timer for turn off:
The unit is run when timer for turn off is acted, the unit is stop, when it is time to turn off. The
distance of setting twice is 0.5hour, and the range time is 0.5~24 hour.
Все каталоги и инструкции здесь:
http
:
//splitoff.ru/tehn-doc.html
Summary of Contents for AC-F30HG
Page 1: ...Air Conditional Service Manual http splitoff ru tehn doc html...
Page 2: ...Model No AC F30HG Version 1 0 2 Model AC F30HG http splitoff ru tehn doc html...
Page 11: ...11 Model No AC F30HG Version 1 0 OUTDOOR UNIT http splitoff ru tehn doc html...
Page 28: ...28 Model No AC F30HG Version 1 0 CIRCUIT DIAGRAM http splitoff ru tehn doc html...