![akira 14LA/ANZ Service Manual Download Page 41](http://html1.mh-extra.com/html/akira/14la-anz/14la-anz_service-manual_2886011041.webp)
-
41
-
Model No.: 14LAANZACDC
Version: 1.0
In “LINE MODE”, beside MUTE button, the following eight buttons will work, with their
function changed as follow. Other buttons will not work.
BUTTON
1 3 5 7
FUNCTION
Sub brig
Red bias +
Green Bias +
Blue Bias +
BUTTON
0 2 4 6
FUNCTION
Sub brightness -
Red bias -
Green bias -
Blue bias -
Item
Screen character display adjustment
Measuring Equipment
Service remote controller
Preparation before Adj.
Brightness, contrast and color should be set in standard
1. Receive Philips circular test signal (PAL system).
2. Use PROD (FACTORY) button to enter into adjusting mode.
3. Press CH± button to select OSD. H. POSI option. Use VOL± button to adjust the value of
OSD.H.POSI till the characters appear in the horizontal center position.
4. Press CH± button on the maintenance use remote controller to select OSD.V.POSI option. Use
VOL± button to adjust the value of OSD.V.POSI to make the characters appear in the vertical
center (i.e. make the caption of characters appear in the center of the caption frame of the
Philips circular test signal).
5. Press CH± button to select OSD.CONT option. Use VOL± to adjust the value of OSD.CONT
till the character display achieves proper brightness.
6. Press PROD (FACTORY) button till exit.