Do not install the detector
Installation and connection
Before installing GlassProtect Fibra, make sure that you have selected the optimal
location and that it meets the requirements of this manual. Wires must be hidden from
view and located in a di cult place for burglars to access to reduce the likelihood of
sabotage. Ideally, the cables should be embedded in the walls, oor, or ceiling. Before
the nal installation, conduct tests of the
and the Fibra signal strength.
When connecting, please do not twist the wires together; solder them. The ends
of the cables that will be inserted into the detector’s terminals should be tinned.
This will ensure a reliable connection.
Follow safety procedures and regulations
for electrical installation work
.
1.
Outdoors. This can lead to false alarms and detector failure.
2.
Close to sirens and alarms. This can lead to false alarms of the break
detector.
3.
In places with fast air circulation. For example, near fans, open windows, or
doors; this can lead to false alarms of the break detector.
4.
In places where objects and structures can block the view of the detector.
For example, behind a ower or a column.
5.
Inside premises with temperature and humidity outside the permissible
limits. This could damage the detector.