To test the break detector:
You can also play this
to imitate the breaking of glass.
Maintenance
Check the functioning of the detector on a regular basis. The optimal frequency
of checks is once every three months. Clean the detector body from dust,
cobwebs, and other contaminants as they emerge. Use a soft dry cloth suitable
for equipment care.
Do not use substances that contain alcohol, acetone, petrol, or other active
solvents to clean the detector.
Technical speci cations
3.
Choose GlassProtect Fibra.
4.
Go to
Settings
.
5.
Choose a test:
Fibra Signal Strength Test
Detection zone
6.
Launch and conduct a test.
1.
Start a detection zone test.
2.
Hit the glass (without breaking it) or another surface with your st. If the
detector microphone catches a low-frequency sound, the LED will blink.
3.
Within 1.5 seconds after the rst impact, simulate the high-frequency sound
of glass breaking by tapping a metal object against a glass or by dropping
keys onto oor tiles.
4.
As soon as the detector reads the sound, it will turn off the LED for a
second. This means that a break alarm has been detected.
Summary of Contents for GlassProtect Fibra
Page 29: ......