10.2 Installation

When  installing  the  tank,  ensure  sufficient  clearance 

from walls and other objects to enable the connection 

pipes to be fitted.

 IMPORTANT

Do not exceed the operating pressures spec-

ified on the rating plate.

 NOTE

Close  off  any  connections  not  required  with 

appropriate plugs or caps.

  Position  of  the  connections:  "Dimensional  draw-

ings“, from page 8, for the respective model

10.3 Installation of the sensor(s)

1.  On site, install the sensor(s) included included in 

the scope of delivery for the heating and heat pump 

regulator in the sensor pocket(s) provided.

  Position: 

"Dimensional 

drawings“, 

from 

page 8, for the respective model.

2.  Connect the sensor(s) to the regulator according 

to the terminal diagram.

  Terminal  diagram  for  the  respective  model  in  the 

heat pump operating manual

11 

Insulation of the connections 

and the storage tank

 NOTE

Insulate  in  accordance  with  applicable  local 

standards and directives.

1.  Check seals of all hydraulic connections. Conduct 

pressure test.

2.  Insulate all connections, pipes and cables.

 IMPORTANT

The insulation of TPSK-/WTPSK tanks of the 

connections and lines must be moistureproof.

12 

Draining the storage tank

 IMPORTANT

When  draining  the  storage  tank,  always  en-

sure adequate ventilation.

Summary of Contents for 813643

Page 1: ...UK 83030000bUK Accessories for heat pumps Operating Manual Buffer Tanks Split ...

Page 2: ...his operating manual is intended only for persons assigned to work on or operate the unit Treat all constituent parts confidentially The information contained herein is protected by copyright No part of this manual may be reproduced transmitted copied stored in electronic data systems or translated into another language either wholly or in part without the express written permission of the manufac...

Page 3: ...isposal 5 9 Scope of delivery 5 9 1 Accessories 5 10 Transport Installation Assembly 5 10 1 Transport to installation location 5 10 2 Installation 6 10 3 Installation of the sensor s 6 11 Insulation of the connections and the storage tank 6 12 Draining the storage tank 6 Technical Data 7 WPSK 40Split WTPSK 101Split 7 Dimensional drawings 8 WPSK 40Split 8 WTPSK 101Split 9 Installation plans 10 WPSK...

Page 4: ...understand the activities and the resulting consequences and can car ry out the necessary activities Children and adults who are not experienced in hand ling the product and do not understand the necessa ry activities and the resulting consequences must be instructed and if necessary supervised by persons experienced in handling the product and who are re sponsible for safety Children must not pla...

Page 5: ...mbly Observe the following when performing all work IMPORTANT The tank must be installed in a frostproof room to prevent frost damage to the storage tank pipe system and connections NOTE Install the storage tank as close as possible to the heat generator to keep the heat losses as low as possible Ensure the shortest pos sible pipe lengths to the load IMPORTANT The floor or ground at the place of i...

Page 6: ...cope of delivery for the heating and heat pump regulator in the sensor pocket s provided Position Dimensional drawings from page 8 for the respective model 2 Connect the sensor s to the regulator according to the terminal diagram Terminal diagram for the respective model in the heat pump operating manual 11 Insulation of the connections and the storage tank NOTE Insulate in accordance with applica...

Page 7: ...ure minimum maximum Tank name Series buffer tank Stratified storage tank Stratified storage tank solar Heating water reservoir Energy efficiency class according to ErP Standing loss according to ErP at 65 C Total tank volume according to ErP Nominal capacity Max operating pressure Test pressure Operating temperature minimum maximum Installation location Insulation Material Rigid foam soft foam She...

Page 8: ...hnischen Änderungen vorbehalten Alle Maße in mm A Vorderansicht C Draufsicht A C 495 330 445 4 3 2 1 Keys UK81513 All dimensions in mm Pos Name Dimension A Front view C Plan view 1 Return from heating R 1 2 Return to heat pump R 1 Net weight 16 kg Nominal volume 39 litres Dimensional drawings WPSK 40Split ...

Page 9: ... 1 3 Fühler Ø i 10mm 4 Rücklauf Heizkreis Wärmepumpe G 1 5 Blindstopfen 6 Vorlauf Wärmepumpe G 1 Nettogewicht 41 kg Nenninhalt 120 Liter 4 3 2 1 A B C D E F 4 3 2 1 Schutzvermerk ISO 16016 beachten Keys UK819533 All dimensions in mm Pos Name Pos Name A Front view C Plan view B Side view from left G Detail view Pos Name Dimension 1 Bleeding G 1 2 2 Flow heating circuit G 1 3 Sensor Ø i 10 mm 4 Retu...

Page 10: ... 490 FS 819515 Änderungen vorbehalten mm nsicht m für Servicezwecke A 5 4 3 2 www D I ait 4 3 2 Zust Änderungstext Datum Von Erstell Gepr Norm to Al DIN IS DM 09 06 20 PEP 013 2019 a Keys UK819515 All dimensions in mm Pos Name A Front view FS Free space for servicing Installation plan WPSK 40Split ...

Page 11: ...920 FS A egende DE819535 Technische Änderungen vorbehalten Alle Maße in mm A Vorderansicht FS Freiraum für Servicezwecke 5 4 3 2 1 4 3 2 1 Zust Änderungstext Datum 27 01 22 p675 Keys UK819535 All dimensions in mm Pos Name A Front view FS Free space for servicing WTPSK 101Split Installation plan ...

Page 12: ...ait deutschland GmbH Industriestraße 3 D 95359 Kasendorf www ait deutschland eu UK ...

Reviews: