3  Intended use

The storage tank may be used only for the intended 

purpose.

This  means  as  a  buffer  storage  tank  in  conjunction 

with:

 

● Air/water Split heat pumps

 

► If  local  regulations  apply,  observe:  laws,  stand-

ards and directives.

Disclaimer

The manufacturer is not liable for losses resulting from 

any use of the unit which is not its intended use.
The manufacturer's liability also expires:

 

● if work is carried out on the unit and its compo-

nents contrary to the instructions in this operat-

ing manual.

 

● if work is improperly carried out on the unit and 

its components.

 

● if work is carried out on the unit which is not de-

scribed in this operating manual, and this work 

has not been explicitly approved by the manu-

facturer in writing.

 

● if the unit or components in the unit have been 

altered, modified or removed without the explicit 

written consent of the manufacturer.

Safety

The unit is safe to operate when used for its intended 

purpose.  The  construction  and  design  of  the  unit 

conform  to  current  state-of-the-art  standards,  all 

relevant  DIN/VDE  regulations  and  all  relevant  safety 

regulations.
The operating manuals supplied with the product are 

intended for all users of the product.
The operation of the product via the heating and he-

at pump control and work on the product which is in-

tended for end customers / operators is suitable for all 

age groups of persons who are able to understand the 

activities and the resulting consequences and can car-

ry out the necessary activities.
Children and adults who are not experienced in hand-

ling the product and do not understand the necessa-

ry activities and the resulting consequences must be 

instructed  and,  if  necessary,  supervised  by  persons 

experienced in handling the product and who are re-

sponsible for safety.
Children must not play with the product.
The product may only be opened by qualified personnel.
All instructional information in this operating manual is 

solely directed at qualified, skilled personnel. 
Only  qualified,  skilled  personnel  is  able  to  carry  out 

the work on the unit safety and correctly. Interference 

by  unqualified  personnel  can  cause  life-threatening 

injuries and damage to property.

 

► Ensure that the personnel is familiar with the  local 

regulations, especially those on safe and hazard-

aware working.

 

► Only  allow  qualified  personnel  with  “electrical” 

training  to  carry  out  work  on  the  electrics  and 

electronics.

 

► Only  allow  qualified,  skilled  personnel  to  do  any 

other work on the system, e.g.

 

● Heating installer

 

● Plumbing installer

 

● Refrigeration  system  installer  (maintenance 

work)

Every person who carries out work on the unit must 

comply  with  the  applicable  accident  prevention  and 

safety  regulations.  This  applies  in  particular  to  the 

wearing of personal protective clothing.
During  the  warranty  and  guarantee  period,  servicing 

and repair work may only be carried out by personnel 

authorised by the manufacturer.

5.1  Personal protective equipment

There is a risk of cutting your hands on sharp edges 

of the unit.

 

► Wear cut-resistant protective gloves during trans-

port.

Summary of Contents for 813643

Page 1: ...UK 83030000bUK Accessories for heat pumps Operating Manual Buffer Tanks Split ...

Page 2: ...his operating manual is intended only for persons assigned to work on or operate the unit Treat all constituent parts confidentially The information contained herein is protected by copyright No part of this manual may be reproduced transmitted copied stored in electronic data systems or translated into another language either wholly or in part without the express written permission of the manufac...

Page 3: ...isposal 5 9 Scope of delivery 5 9 1 Accessories 5 10 Transport Installation Assembly 5 10 1 Transport to installation location 5 10 2 Installation 6 10 3 Installation of the sensor s 6 11 Insulation of the connections and the storage tank 6 12 Draining the storage tank 6 Technical Data 7 WPSK 40Split WTPSK 101Split 7 Dimensional drawings 8 WPSK 40Split 8 WTPSK 101Split 9 Installation plans 10 WPSK...

Page 4: ...understand the activities and the resulting consequences and can car ry out the necessary activities Children and adults who are not experienced in hand ling the product and do not understand the necessa ry activities and the resulting consequences must be instructed and if necessary supervised by persons experienced in handling the product and who are re sponsible for safety Children must not pla...

Page 5: ...mbly Observe the following when performing all work IMPORTANT The tank must be installed in a frostproof room to prevent frost damage to the storage tank pipe system and connections NOTE Install the storage tank as close as possible to the heat generator to keep the heat losses as low as possible Ensure the shortest pos sible pipe lengths to the load IMPORTANT The floor or ground at the place of i...

Page 6: ...cope of delivery for the heating and heat pump regulator in the sensor pocket s provided Position Dimensional drawings from page 8 for the respective model 2 Connect the sensor s to the regulator according to the terminal diagram Terminal diagram for the respective model in the heat pump operating manual 11 Insulation of the connections and the storage tank NOTE Insulate in accordance with applica...

Page 7: ...ure minimum maximum Tank name Series buffer tank Stratified storage tank Stratified storage tank solar Heating water reservoir Energy efficiency class according to ErP Standing loss according to ErP at 65 C Total tank volume according to ErP Nominal capacity Max operating pressure Test pressure Operating temperature minimum maximum Installation location Insulation Material Rigid foam soft foam She...

Page 8: ...hnischen Änderungen vorbehalten Alle Maße in mm A Vorderansicht C Draufsicht A C 495 330 445 4 3 2 1 Keys UK81513 All dimensions in mm Pos Name Dimension A Front view C Plan view 1 Return from heating R 1 2 Return to heat pump R 1 Net weight 16 kg Nominal volume 39 litres Dimensional drawings WPSK 40Split ...

Page 9: ... 1 3 Fühler Ø i 10mm 4 Rücklauf Heizkreis Wärmepumpe G 1 5 Blindstopfen 6 Vorlauf Wärmepumpe G 1 Nettogewicht 41 kg Nenninhalt 120 Liter 4 3 2 1 A B C D E F 4 3 2 1 Schutzvermerk ISO 16016 beachten Keys UK819533 All dimensions in mm Pos Name Pos Name A Front view C Plan view B Side view from left G Detail view Pos Name Dimension 1 Bleeding G 1 2 2 Flow heating circuit G 1 3 Sensor Ø i 10 mm 4 Retu...

Page 10: ... 490 FS 819515 Änderungen vorbehalten mm nsicht m für Servicezwecke A 5 4 3 2 www D I ait 4 3 2 Zust Änderungstext Datum Von Erstell Gepr Norm to Al DIN IS DM 09 06 20 PEP 013 2019 a Keys UK819515 All dimensions in mm Pos Name A Front view FS Free space for servicing Installation plan WPSK 40Split ...

Page 11: ...920 FS A egende DE819535 Technische Änderungen vorbehalten Alle Maße in mm A Vorderansicht FS Freiraum für Servicezwecke 5 4 3 2 1 4 3 2 1 Zust Änderungstext Datum 27 01 22 p675 Keys UK819535 All dimensions in mm Pos Name A Front view FS Free space for servicing WTPSK 101Split Installation plan ...

Page 12: ...ait deutschland GmbH Industriestraße 3 D 95359 Kasendorf www ait deutschland eu UK ...

Reviews: