background image

NO INDOOR BLOWER HIGH SPEED 

COOLING MODE OR FAN ONLY 

 

 

Note:  All operating functions subject to thermostat and printed circuit board time delays. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-10- 

115 VAC To Air 

Conditioner 

NO 

Does APU Have Auto 

Generator Start? 

NO 

Start Generator OR 

Refer To Generator 

Service Manual 

YES 

YES 

12 VDC At Thermostat Wiring 

Plug At Unit Red And Blue 

NO 

Restore 12 VDC R+ B- 

12 VDC At Thermostat Wiring Plug At Unit 

There Are 2 Parallel Circuits To Energize Indoor Blower High Speed.  This Is To Accommodate Auto 

Gen Start Feature And Enable Motor To Run In Fan Only Operation If 115 VAC Is Already Present 

12 VDC P.C. Board  

GH & B 

YES 

Fan Only 

Green & Blue 

Cooling Mode 

Yellow & Blue 

YES 

12 VDC At P.C. 

Board GH & B 

Refer To Auto Gen Checkout 

115 VAC At 

P.C. Board 

High 

NO 

Check Low 

Voltage Wiring 

To Indoor Blower 

Relay 

Check Wiring And Connectors To 

And At Thermostat.  If All Are 

Good, Replace Thermostat 

YES 

NO 

YES 

NO 

Check All 115 VAC Wiring 

To P.C. Board Line 1 & Line 

2.  If Wiring Is Good, 

Replace P.C. Board. 

YES 

NO 

Refer To No 

Compressor 

Operation 

115 VAC 

At P.C. 

Board High 

YES 

NO 

Check All 115 

VAC Wiring To 

P.C. Board L1 & 

L2 

Check Wiring And 

Connections And 

Fix As Needed 

Check Wiring To Motor.  

Check Capacitor, Motor 

Windings.  Fix Or Replace  

NO 

YES 

Replace P.C. Board 

Check Wiring To Motor.  

Check Capacitor, Motor 

Windings.  Fix Or 

Replace As Necessary. 

Summary of Contents for 46101-8114

Page 1: ...Associated Products Division SERVICE MANUAL FOR 46101 8114 46103 8114 BACKWALL AIR CONDITIONING SYSTEM...

Page 2: ...ERE PERSONAL INJURY DEATH OR EQUIPMENT DAMAGE DUE TO ELECTRICAL SHOCK ALWAYS BE SURE THE POWER SUPPLY TO THE APPLIANCE IS DISCONNECTED BEFORE DOING ANY WORK ON THE APPLIANCE THIS CAN NORMALLY BE ACCOM...

Page 3: ...3 UNIT SPECIFICATIONS AND IDENTIFICATION 3...

Page 4: ...4 UNIT DEPICTION FIGURES 4...

Page 5: ...pre charged unit designed to hang vertically on the back wall of a sleeper cab It is designed to be easily accessed for service and can be removed quickly for service or replacement All the electrica...

Page 6: ...6...

Page 7: ...7...

Page 8: ...ndoor Blower High NO Refer To Indoor Blower High Checkout 15 Second Time Delay Compressor Outdoor Fan NO Refer To Outdoor Fan Checkout NO Refer To Compressor Checkout Thermostat Call Generator Start O...

Page 9: ...ward on any chart until all preceding steps have been confirmed good Do Not start in the middle of any chart without knowing everything previous upward on the chart is OK or you may replace the wrong...

Page 10: ...15 VAC Is Already Present 12 VDC P C Board GH B YES Fan Only Green Blue Cooling Mode Yellow Blue YES 12 VDC At P C Board GH B Refer To Auto Gen Checkout 115 VAC At P C Board High NO Check Low Voltage...

Page 11: ...d Connectors To Plug And Thermostat Repair As Needed If All Are Good Replace Thermostat YES 12 VDC At P C Board Y B YES 115 VAC P C Board Compressor Relay COM Check Compressor 1 Start Relay Check For...

Page 12: ...On Wall Thermostat Plug At Unit YES 12 VDC At 4 Pin Plug Red Black NO Check All Wiring And Connections From Indoor Section To Thermostat Repair As Needed If All Are Good Replace Thermostat YES Refer...

Page 13: ...rd WI NO Check Wiring And Connections From Thermostat Wiring Plug Gray Wire To W1 If Wiring Is Good Replace P C Board YES Is Indoor Low Speed Running Thermostat Set For Low Heat Thermostat Set For Hig...

Page 14: ...ow Checkout then proceed below 12 VDC At P C Board GL B YES NO Check All Wiring And Connections From GL On P C Board 115 VAC At P C Board Low YES Check Wiring To Motor Check Capacitor Motor Windings F...

Page 15: ...10 CONTROL BOX COMPONENTS 15 15...

Page 16: ...r W1 1st Stage Heat Signal From Thermostat W2 2nd Stage Heat Signal From Thermostat GH Indoor Blower Signal From Thermostat Y Compressor Signal From Thermostat Power To Compressor Power To 2nd Stage H...

Page 17: ...11 WIRING DIAGRAM 17...

Page 18: ...Associated Products Division Airxcel Inc Associated Products Division P O Box 4020 Wichita KS 67204 1976 607 3 12...

Page 19: ......

Reviews: