![Airwell YAF018 Service Manual Download Page 51](http://html1.mh-extra.com/html/airwell/yaf018/yaf018_service-manual_2879929051.webp)
12-20
CONTROL SYSTEM
SM HAFRPM 2-A.1 GB
12.8
Protection
12.8.1
Cooling Mode Protections
1. Indoor Coil Defrost
Mode: Cooling, Dry, Auto
Temp: Selected desired temp.
Fan: Any
Timer: Any
I Feel: On or Off
Control Function
Protect the indoor coil from ice formation at low ambient temperature.
ICT [
o
c]
+2
ON
OFF
ON
OFF
t1
t2
t3
COMP
OFAN
+1
+5
+14
0
-1
ON
OFF
IFAN
t1
t1 = 5 min minimum for each COMP starting
t2 = OFAN cycling (alternate between ON and OFF every 30 sec) for 20 min maximum
t3 = COMP and OFAN stop for 10 min minimum