Mode Operation
conditions
Protection
from
Controlled
remedy
Your air-conditioner includes several auto protection modes which enables you to use
it virtually at any time and in any season regardless of the outdoor temperature. Some of the protec-
tion modes are listed below:
PROTECTION MODES
Cooling and
Dry
Low outdoor
temperature
Indoor coil
freezes up
Stops outdoor fan and compressor when
approaching freezing conditions
Resumes operation automatically.
High outdoor
temperature
Outdoor coil
overheating
Heating
Low outdoor
temperature
Outdoor coil
ice build up
Stops outdoor fan and compressor when
approaching high indoor coil temperature.
Resumes operation automatically.
High Indoor
or outdoor
temperature
Indoor coil
overheating
Reverses operation from heating to
cooling for short periods to de-ice outdoor
coil.
Operating indicator (A) blinks.
Stop compressor when approaching
over heating conditions.
Resumes operation automatically.
Operating indicator (A) blinks.
15