ASSEMBLY OF THE DRAINPIPE
Connect the drainpipe with the flexible tube in the seat at the rear of the indoor unit .
1
2
3
Place the pipe against the hydraulic pipes and the electric cables.
Check that the drainpipe is running downwards.
Avoid siphons and bends when installing the drainpipe.
The end of the pipe should be under waterlevel.
For an outlet at the left, lay the drainpipe in the seat at the rear of the unit .
If the location selected requires to use long horizontal sections of the drainpipe, provide for an opening at the top
of the pipe to avoid overflow of the condensing tray.
After having finished the installation, test the draining by pouring at least two liters of water into the condensing
tray. Check that water is freely being drained.
1
Opening
2
Draining condensates downwards
3
Drainpipe
1
Drainpipe
2
Fastening clip
3
Downwards plane
Possible outlets of hydraulic pipes
1
Electric cable
2
Hydraulic pipe
3
Drainpipe
1
Siphon
2
Bend
3
End dipping into water