5-1
PERFORMANCE DATA & PRESSURE CURVES
SM XLFDCI 1-A.1 GB
5.
PERFORMANCE DATA & PRESSURE CURVES
5.1
XLF 9 DCI / GC 9 R410A
5.1.1
Cooling Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
Entering Air DB
OD Coil(
o
C)
Data
Entering Air WB/DB ID Coil(
o
C)
15/21
17/24
19/27
21/29
23/32
15
TC
2.58
2.73
2.86
2.99
3.09
SC
1.89 2.00
2.11
2.06
2.09
PI
0.47 0.48
0.48
0.48
0.48
20
TC
2.56
2.71
2.83
2.96
3.06
SC
1.82
1.94
2.05
1.99
2.03
PI
0.51
0.52
0.52
0.52
0.52
25
TC
2.45
2.63
2.78
2.91
3.01
SC
1.83
1.96
2.08
2.04
2.09
PI
0.55
0.56
0.56
0.57
0.57
30
TC
2.30
2.48
2.68
2.78
2.88
SC
1.74
1.88
2.03
1.99
2.07
PI
0.60
0.61
0.61
0.62
0.62
35
TC
2.13
2.30
2.53
2.66
2.76
SC
1.64
1.78
1.95
1.93
2.01
PI
0.65
0.66
0.67
0.66 0.68
40
TC
1.92
2.10
2.33
2.45
2.56
SC
1.52
1.68
1.84
1.82
1.90
PI
0.70
0.71
0.72
0.73
0.73
46
TC
1.67
1.85
2.07
2.20
2.30
SC
1.38 1.54
1.73
1.70
1.78
PI
0.77
0.78
0.79
0.80
0.81
LEGEND
TC – Total Cooling Capacity, kW
SC – Sensible Capacity, kW
PI – Power Input, kW
WB – Wet Bulb Temp., (
o
C)
DB – Dry Bulb Temp., (
o
C)
ID – Indoor
OD – Outdoor
(1) Marked area is below standard operating limits. For operating in low ambient
conditions, refer to Optional Accessories (Chapter 15).