background image

3

INTRODUCTION

1. DEFINITION

The 

X 2450

 

 and 

X 3250

 

packaged air conditioners

are presented :

• Single packaged for the 

WATER

 

 cooled models

(

AO

),

• with a separate outdoor condensing unit for the

AIR

 cooled models (

AR

).

The air intake and discharge is provided :

• either directly by air intake grilles and a discharge

plenum (accessory),

• or  by  ducts  for  intake  and/or  discharge,  to  be

connected to the connection flanges (accessory).

This well-finished, single packaged unit combines

many  features  such  as  easy  installation,  high

efficiency, quiet operation and reliability, which make

it well suited for air conditioning, dehumidification

and  air  filtering  in  offices,  stores  and  industrial

premises.

These packaged air conditioners can be equipped

with the following accessories :

• Electric heater (integrated),

• Hot water coil,

• A 4-stage thermostat to be integrated,

• A 4-stage remote control thermostat,

• A double-deflection discharge plenum,

• 90% gravimetric air filters.

They  benefit  from  30  years  experience  and  are

perfectly suited to working with :

• Wasted water; its consumption being reduced to

a minimum by a pressure valve (included in the

AO

-wasted water model).

• Recycled water; supplied by a cooling tower or an

outdoor heat exchanger.

• Outside air with the possibility of operating at very

low  temperatures  (down  to  –10°C  with  the  “ALL

SEASONS” option on the 

AR

 

models).

2. MAIN DATA

• Cabinet with reduced floor dimensions.

• Standard ventilation :

Basic  with  drive  motor  and  transmission  by

ajustable pulley/belt.

• “High  ventilation  equipment  available  as  option

providing a greater available pressure.

• Vertical blowing with duct or plenum (accessory).

• Two air intake possibilities :

On the front with grilles or on the rear with ducts,

with the rear air intake (accessory).

• Heat lagged filters M1, regenerable, mounted on

metal  frame  :  2  efficiency  ratings,  83  ou  90%

gravimetric.

• Electrical,  hydraulic  and  refrigerant  connections

on right or left.

• Cooling by wasted water with pressure controlled

valve or by recycled water without valve.

• Possibility of running in cooling mode down to an

outdoor temperature of –10° C for the 

AR

 models

with the “ALL SEASONS” accessory.

• Two heating possibilities (accessories) :

– basic built-in

(see 14, "CONTROLS  AND REGULATION",

– to be built-in as an accessory with 4 stages and

a neutral zone,

– with remote control, as an accessory, with 4 sta-

ges and a neutral zone.

• Two control possibilities (accessory):

Integrated  electrical  heating  coils  or  hot  water

heating coils.

• Two refrigerant connection pipe possibilities (

AR

models): up to 25 m maximum with factory pre-

charged pipes (accessory) or with pipes brazed

and charged on site (set of female valves supplied

as an accessory for connections up to 45 m).

3. DESCRIPTION

3.1 Bodywork

• Panels and side faces made of profiled sheet steel

covered  with  enamel  finish,  baked  in  a  high

temperature oven.

• Intake  grilles  made  of  modular  elements  in

flameproof, shock resistant polystyrene, classified

UL-VO according to UL94.

3.2 Insulation and protection

• Thermal and acoustic insulation of the unit.

• Watertight unit base for the possible collection of

condensates  or  abnormal  overflowing  (e.g.

condensate drain tray clogging).

3.3 Refrigerant circuit

• All models

Simple refrigerating circuit, each including :

– Hermetic type compressor fitted with thermal and

electrical protections, linked to a factory sealed

and brazed cooling circuit.

– Pressostats and high and low pressure measu-

rement Schrader valves.

– Copper tube evaporator with aluminium fins and

anti-corrosion protected condensate tray.

· AR / AO Model

– Reserve liquid receiver.

– Thermostatic pressure reducer with pressure

balancing.

– Liquid indicator and valve on liquid line.

"  When  the  HCFC  fluids  are  replaced,  these  appliance  have  been

optimized to operate with the R-407C coolant which contains no chlorine

and has no effect on the ozone layer."

Summary of Contents for X2450

Page 1: ...VERTICALUNITS X2450 X3250 air cooled AR water cooled AO PACKAGED AIR CONDITIONERS Technical Manual 00TX04...

Page 2: ...ION 17 Outdoor condensing unit Type UC 73A Outdoor condensing unit Type UC 103A REFRIGERATION PIPEWORK Model AR 18 ELECTRICAL CONNECTIONS Main power supply 19 ELECTRICAL SPECIFICATIONS Main power supp...

Page 3: ...ncy ratings 83 ou 90 gravimetric Electrical hydraulic and refrigerant connections on right or left Cooling by wasted water with pressure controlled valve or by recycled water without valve Possibility...

Page 4: ...f the fan motors VS and FV by fuses and an internal safety device Low pressure pressostats with automatic reset and high pressure pressostats with manual reset Solenoid shut off valve on the liquid li...

Page 5: ...lation equipment Mini Maxi W W 500 1100 800 1800 700 1800 1100 2200 SOUND PRESSURE INDOOR UNIT 3 Normal speed dBA 59 58 65 64 ELECTRIC POWER SUPPLY Nominal voltage Voltage range V 3N 400 V 50 Hz 360 4...

Page 6: ...897 13171 13446 13720 13994 14269 27 14444 14758 15072 15386 15700 16014 16328 29 16266 16619 16973 17326 17680 18034 18196 31 18087 18480 21380 20602 19800 18998 18196 21 PT W 24363 23522 22680 21839...

Page 7: ...17094 17450 17806 18162 18519 23 18894 19305 19716 20126 20537 20948 21359 25 21406 21872 22337 22803 23268 23733 24199 27 23919 24439 24959 25479 27308 26177 25046 29 30392 30392 29570 28439 27308 26...

Page 8: ...12 Water consumption l h 903 1058 1395 PA W 6467 Water pressure kPa 18 25 43 23 PS W 8045 25 10486 27 12927 29 15368 31 17810 33 20251 23 PT W 25837 Water consumption l h 954 1117 1473 PA W 6774 Water...

Page 9: ...48 Water consumption l h 1259 1474 1944 PA W 8706 Water pressure kPa 19 26 46 23 PS W 10259 25 13694 27 17129 29 20564 31 23999 33 27433 23 PT W 36306 Water consumption l h 1328 1555 2050 PA W 9090 Wa...

Page 10: ...gh Ventilation FV Motor 1 5 kW Rotation speed turbine r p m Mini Maxi Mini Maxi 750 1025 1000 1315 Available static pressure daPa without accessory Nominal flow 4500 m3 h 0 15 12 37 Minimum flow 3600...

Page 11: ...LVE SV TH 3109 X 2450 X 3250 100 kPa 1 bar WATER SUPPLY WASTED WATER MODELS X 2450 X 3250 NOMINAL WATER FLOW AIR TO BE TREATED 27 C 47 m3 h 1 45 2 00 NOMINAL WATER TEMPERATURE Inlet C Outlet C 15 WATE...

Page 12: ...ture Twe C 90 Mini dry indoor temperature Tsi C 6 Connection mm F33 x 42 1 1 4 X 2450 X 3250 Protection anti freeze Note Anti freeze mandatory in summer and winter Pt kW Model X 3250 Ex Tsi 20 C Water...

Page 13: ...E DISCHARGE ELECTRICAL HEATER HOT WATER COIL ACCESSORIES Marks Models X 2450 X 3250 1 HOT WATER COIL Nominal power input Nominal water flow Water pressure loss kW m3 h kPa 38 5 3 3 24 50 4 3 44 Connec...

Page 14: ...zone accessory with 4 stages accessory Fault ventilation Fault compressor HP pressure switch and thermic compressor NOTES With the automatic Cooling Heating thermostat with neutral zone supplied with...

Page 15: ...ke grille Connection for fresh air intake accessory not supplied on left or right Access panel to the electrical and refrigeration compartments Connections for electric hydraulic and refrigerating lin...

Page 16: ...ISCHARGE DUCT CONNECTION FLANGE FRONT REAR REAR FRONT TOP VIEW REAR VIEW DIMENSIONS INSTALLATION Air treatment unit Models A B C D E F G H J X 2450 452 812 738 321 121 441 170 115 244 X 3250 1042 956...

Page 17: ...760 H 230 X 2450 1 x UC 73A CLEARANCES TO BE PROVIDED Top 2 50 m FLOOR MOUNTING AND FIXING 2 possibilities 4 oblongs holes 9 x 16 Outdoor condensing unit Type UC 103A X 3250 Model AR UC 73A Air flow...

Page 18: ...nit 5220 6615 CONDENSER AT THE SAME LEVEL AS THE INDOOR UNIT CONDENSER INDOOR UNIT CONDENSER HIGHER THAN THE INDOOR UNIT CONDENSER INDOOR UNIT CONDENSER LOWER THAN THE INDOOR UNIT INDOOR UNIT CONDENSE...

Page 19: ...se 230 V for a three phase 230 V cabinet INTERCONNECTIONS WITH REMOTE AMBIENT THERMOSTAT Accessory Cooling regulation stage F2 N 2 available for mono compressor models X 2450 X 3250 SG GENERAL SELECTO...

Page 20: ...45 154 63 16 18 7 19 3 50 53 59 62 124 133 63 16 18 7 19 3 29 31 33 35 83 86 40 10 18 7 19 3 29 31 33 35 71 74 40 10 23 4 24 3 63 74 74 76 200 220 80 25 23 4 24 3 63 74 74 76 176 196 80 25 23 4 24 3 3...

Page 21: ...1 bis Avenue du 8 Mai 1945 Saint Quentin en Yvelines 78284 GUYANCOURT Cedex T l 01 39 44 78 00 Fax 01 39 44 11 55...

Reviews: