5-11
PERFORMANCE DATA & PRESSURE CURVES
Service Manual - DUO Series
5.5
DUO WNG (9+9):Room A + Room B
5.5.1
Cooling Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR
DB OU COIL (°C)
DATA
ENTERING AIR WB/DB ID COIL ( °C)
15/21
17/24
19/27
21/29
23/32
15
(1)
TC
6.03 6.24 6.39 6.54 6.64
SC
4.18 4.36 4.53 4.64 4.73
PI
1.35 1.35 1.35 1.36 1.36
20
(1)
TC
5.83 6.15 6.34 6.49 6.63
SC
4.10 4.32 4.50 4.63 4.72
PI
1.46 1.47 1.47 1.48 1.48
25
TC
5.52 5.96 6.27 6.45 6.61
SC
3.99 4.24 4.47 4.60 4.68
PI
1.58 1.59 1.60 1.61 1.62
30
TC
5.16 5.62 6.07 6.29 6.47
SC
3.87 4.11 4.37 4.50 4.58
PI
1.70 1.73 1.74
1.76 1.77
35
TC
4.78 5.19
5.72
6.01 6.29
SC
3.68 3.94
4.27
4.39 4.48
PI
1.84 1.87
1.90
1.91 1.93
40
TC
4.35 4.73 5.16
5.64 5.93
SC
3.47 3.73 4.04 4.17 4.25
PI
1.98 2.01 2.05 2.07 2.09
46
TC
3.77 4.12 4.53 5.01 5.40
SC
3.19 3.42 3.68 3.81 3.90
PI
2.17 2.20 2.25 2.28 2.31
LEGEND
TC –
Total Cooling Capacity, kW
SC – Sensible
Capacity,
kW
PI –
Power Input, kW
WB – Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor
Summary of Contents for WNG12