5-1
PERFORMANCE DATA & PRESSURE CURVES
SM VAR 1-A.1 GB
5.
PERFORMANCE DATA & PRESSURE CURVES
5.1
Model: VAR 9 ST/RH
5.1.1
Cooling Capacity (kW) Cooling Mode
230V : Indoor Fan at High Speed.
Entering Air DB
OD Coil(
o
C)
Data
Entering Air WB/DB ID Coil(
o
C)
15/21
17/24
19/27
21/29
23/32
15
TC
2.66 2.75 2.82 2.88 2.93
SC
1.72 1.80 1.87 1.91 1.95
PI
0.69 0.69 0.69 0.69 0.70
20
TC
2.57 2.71 2.79 2.86 2.92
SC
1.69 1.78 1.86 1.91 1.94
PI
0.75 0.75 0.75 0.76 0.76
25
TC
2.43 2.63 2.76 2.84 2.91
SC
1.65 1.75 1.84 1.89 1.93
PI
0.81 0.81 0.82 0.82 0.83
30
TC
2.27 2.48 2.67 2.77 2.85
SC
1.59 1.69 1.80 1.85 1.89
PI
0.87 0.88 0.89 0.90 0.91
35
TC
2.11 2.28
2.52
2.65 2.77
SC
1.52 1.63
1.76
1.81 1.85
PI
0.94 0.95
0.97
0.98 0.98
40
TC
1.91 2.08 2.27 2.49 2.61
SC
1.43 1.54 1.67 1.72 1.75
PI
1.01 1.03 1.05 1.06 1.07
LEGEND
TC –
Total Cooling Capacity, (kW)
SC – Sensible
Capacity,
(kW)
PI –
Power Input, kW
WB – Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OD –
Outd
OU –
Outdoor
(1) Marked area is below standard operating limits.