ELB:Electricity Leakage Breaker. 

AH  : Assistant heater.

Electrical characteristics

Specifications for field supplied ELB and wire

Unit

Power supply

Fan motor

Model

Hz

Volts

MCA

MFA

KW

FLA

SXV007

50

220~240

0.37

16

0.06

0.18

SXV009

0.37

16

0.06

0.18

SXV012

0.37

16

0.06

0.18

SXV015

0.68

16

0.13

0.41

SXV018

0.68

16

0.13

0.41

SXV021

0.68

16

0.13

0.41

SXV024

0.68

16

0.13

0.41

Model

Power supply wiring

Remote controller wiring

communication wiring

Field ELB

Wire and Size

Wire

Size

SXV007

16A

Must comply

with maximum

current and local

codes(0.75mm

2

 )

Twisted-pair wires

1.0mm

2

SXV009
SXV012
SXV015
SXV018
SXV021
SXV024

NOTE:

 All  field  supplied  parts  and  materials  and 

electrics works must conform to local codes.

 Use copper wire only.

 All wiring must be performed by an authorized 

electrician.

 Every  indoor  unit  must  have  a  sub  circle 

breaker and the whole system must have a 

main circle breaker.

 Be sure to ground the air conditioner.

� 

 

The appliance shall be installed in accordance 

with national wiring regulations ,and shall be 

provided to ensure all-pole disconnection from 

the supply mains, and distance between the 
poles shall be more than 3 mm .

MCA : Min. Circuit Amps (A)

MFA  : Max. Fuse Amps(A)

KW   : Fan Motor Rated output(KW) 

FLA   : Full Load Amps(A)

CHECK ITEMS

     NOTE:

     For the piping and wiring methods,leakage test,vacuum process and installation setting 

     through HMI, please refter to “Outdoor unit Installation Manual”.

Power  supply

Main   R/C

Bus    Wiring

   BEFORE POWER ON

■  Is there any gas leakage at flare nut connections?

■  Has the heat insulation been carried out at flare nut connection? 

■  Is the connecting cable being fixed to terminal board firmly? 

■  Is the connecting cable being clamped firmly?

■  Is the drainage ok? (Refer to "Drainage test  section) 

■  Is the earth wire connection properly done?

■  Is the indoor unit properly hooked to the installation plate?

■  Is the power supply voltage complied with rated value?

  AFTER POWER ON

■  Is there any abnormal sound?

■  Is the cooling operation normal?

■  Is the thermostat operation normal?

■  Is the remote control's LCD operation normal?