1
SELECT THE BEST LOCATION
2
INSTALLATION Of uNIT SuppOrT
Required tools for installation works
Attached accessories
No .
Accessories parts
Qty.
No .
Accessories parts
Qty.
No .
Accessories parts
Qty.
1
Mounting plate
1
2
Tube locating template
1
3
Unit operation manual
Installation manual
2
�
There should not be any heat source or steam near the unit.
�
There should not be any obstacles blocking the air circulation.
�
A place where air circulation in the room is good.
�
A place where drainage can be easily done.
�
Do not install the unit near the door way.
�
Recommended installation height for indoor unit shall be at least 2.3m( for ceiling unit ).
�
Install the wall support of the SXV using the installation template supplied with the unit. (Fig 1)
�
The cut-outs for the unit are shown on this template.
�
Reminder of MINIMUM clearances to be provided. (Fig 2)
�
Coolant connections can be made on the LH side, on the RH side or at the rear. (Fig 3)
�
Condensate evacuation possibilities: right, left, rear and front in the case of a ceiling mounted unit. (2 condensate outputs are available on the recovery tray).
80mm
190mm
900mm
200mm
50mm: ceiling mounted
20mm: flooring mounted
630mm
Liquid
pipe
Model SXV 007/009/012 A= 820mm B= 660mm
Model SXV 015/018/021/024 A= 1200mm B= 1040mm
Indoor unit dimensions=A
Fixing bolt pitch = B
Fixing
bolt
pitch
=
300mm
Fixing
bolt
pitch
=
300mm
Fresh air intake
Connection to the SXV to be
MANDATORILY insulated
RH output
Output to rear
RH and LH outputs of condensate
recovery tray
Condensate output in the case of
a ceiling mounted unit
LH output
Fig 1
Fig 2
Fig 3
1.Screw driver
4.Hexagonal wrench
7. Knife
2.Electric drill, hole core drill ( 60 mm)
5.Pipe cutter
8.Measuring tape
3.Spanner
6.Reamer
9.Torque wrench