background image

1

SELECT THE BEST LOCATION

2

 INSTALLATION Of uNIT SuppOrT

Required tools for installation works 

Attached accessories

No .

Accessories parts

Qty.

No .

Accessories parts

Qty.

No .

Accessories parts

Qty.

1

Mounting plate   

1

2

Tube locating template 

1

3

Unit operation manual

Installation manual 

2

 There should not be any heat source or steam near the unit.

 There should not be any obstacles blocking the air circulation.

 A place where air circulation in the room is good.

 A place where drainage can be easily done.

 Do not install the unit near the door way.

 Recommended installation height for indoor unit shall be at least 2.3m( for ceiling unit ). 

 Install the wall support of the SXV using the installation template supplied with the unit. (Fig 1)

 The cut-outs for the unit are shown on this template.

 Reminder of MINIMUM clearances to be provided. (Fig 2)

 Coolant connections can be made on the LH side, on the RH side or at the rear. (Fig 3)

 Condensate evacuation possibilities: right, left, rear and front in the case of a ceiling mounted unit. (2 condensate outputs are available on the recovery tray).

80mm

190mm

900mm

200mm

50mm: ceiling mounted

20mm: flooring mounted

630mm

Liquid

 pipe

Model SXV 007/009/012            A= 820mm   B= 660mm

Model SXV 015/018/021/024     A= 1200mm B= 1040mm

Indoor unit dimensions=A

Fixing bolt pitch = B

Fixing

 bolt

 pitch

 =

 300mm

Fixing

 bolt

 pitch

 =

 300mm

Fresh air intake

Connection to the SXV to be 

MANDATORILY insulated

RH output

Output to rear

RH and LH outputs of condensate 

recovery tray

Condensate output in the case of 

a ceiling mounted unit

LH output

Fig 1

Fig 2

Fig 3

1.Screw driver 

4.Hexagonal wrench 

7. Knife 

2.Electric drill, hole core drill ( 60 mm) 

5.Pipe cutter 

8.Measuring tape 

3.Spanner 

6.Reamer 

9.Torque wrench 