12-25
CONTROL SYSTEM
Revision 0
Service Manual - EDS
12.11.2
Time adjustment in Sleep Mode
The user can make use of the Off-Timer to extend the Sleep Time from 7 hours to 12
hour (max). The operation of the new “Extended Sleep Mode” is illustrated by the
graphs below.
Case 1 is the Standard Sleep Mode, which is the only sleep mode in previous version
of MCU. The A/C unit simply works for 7 hours, then goes to SB.
Case 2 is the new Extended Sleep Mode. If an active Off-Timer is set to turn off the
A/C between 7-12 hour, relative to the starting of Sleep, the Sleep time is extended.
And, instead of going to SB at the 7th hour, the A/C will work until reaching the Off-time.
Case 3 is an exception to case 2. The Sleep Mode will not be extended to the Off-Time
when the Off-Timer is preceded by an On-Timer, which is also between 7-12 hour.
Oper
Time [Hr]
2
1
0
1
8
4
6
2
Start
Sleep
7
Case 1 : Standard Sleep Mode
Condition : Off-timer is not set or is beyond 12 hour.
SB
Oper
Time [Hr]
2
1
0
1
8
4
6
2
Start
Sleep
7
Case 2 : Extended Sleep Mode
Condition : Off-timer is set at 7-12 hour.
SB
Off-timer
Oper
Time [Hr]
2
1
0
1
8
4
6
2
Start
Sleep
7
Case 3 : Exception to Case 2
Condition : Off-timer is set at 7-12 hour
On-timer is set at 7-12 hour and before Off-timer
SB
Off-timer
On-timer
Summary of Contents for ONG3-18
Page 39: ...8 2 WIRING DIAGRAMS Revision 0 Service Manual EDS 8 2 Indoor Unit EDS100 EDS120 ...
Page 40: ...8 3 WIRING DIAGRAMS Revision 0 Service Manual EDS 8 3 Outdoor unit GCN9 GCN12 ...
Page 41: ...8 4 WIRING DIAGRAMS Revision 0 Service Manual EDS 8 4 Outdoor unit GC10 34 GC45 ...
Page 42: ...8 5 WIRING DIAGRAMS Revision 0 Service Manual EDS 8 5 Outdoor unit ONG3 17 ...
Page 43: ...8 6 WIRING DIAGRAMS Revision 0 Service Manual EDS 8 6 Outdoor unit GCZ22 ...
Page 113: ... 2 MODES OF OPERATION FUNCTIONS AND FEATURES ...