GENERAL RECOMMENDATIONS

- Congratulations for having selected an Airwell  

Airwell  

Airwell  

Airwell  

Airwell  air conditioner.

SAFETY DIRECTIONS

- Follow the safety rules in force when you are working on your

appliance.

- Installation and maintenance of the equipment should be

performed by qualified specialists.

- Make sure that the power supply and its frequency are

adapted to the required electric current of operation, taking
into account specific conditions of the location and the current
required for any other appliance connected with the same
circuit.

WARNING

- Cutoff power supply before starting to work on the appliance.
- The manufacturer declines any responsibility and the warranty

becomes void if these instructions are not respected.

- If you meet a problem, please call the Technical Department

of your area.

- If possible, assemble the mandatory or optional accessories

before placing the appliance on its final location.(see instruc-
tions provided with each accessory)

- The information contained in these Instructions are subject to

modification without advance notice.

IT IS MANDATYORY TO CUTOFF

POWER  SUPPLY BEFORE STARTING

TO WORK IN THE ELECTRIC CASING

BOXES.

K INST. MENU

Summary of Contents for K 30 RCF

Page 1: ...nnections Servicing 4 5 6 7 8 8 9 10 10 11 12 14 15 16 CONTENTS SPLIT DUCTED UNITS For information on control options and P C Board refer to Electronic Controls and Control Options for KRS Controllers Manual Part No TH 3451 A 3990038A Uncontrolled Document for Information Purposes August 2003 A fresh approach to air conditioning INDOOR MODEL OUTDOOR MODEL HEATPUMP K 30 RCF GC30RCFA GC30RCC K 45 RC...

Page 2: ...onal legislation transposing them Machines Directive 98 37 ECC Low tension Directive DBT 73 23 EEC Electromagnetic compatibility Directive 89 336 EEC Pressurised Equipment Directive DESP 97 23 CEE sub module A category I and that the following paragraphs of the harmonized standards have been applied NF EN 60 204 1 1998 NF EN 60 335 1 1995 NF EN 60 335 2 40 1994 NF EN 55 022 1998 NF EN 61 000 3 2 1...

Page 3: ...rent required for any other appliance connected with the same circuit WARNING Cutoff power supply before starting to work on the appliance The manufacturer declines any responsibility and the warranty becomes void if these instructions are not respected If you meet a problem please call the Technical Department of your area If possible assemble the mandatory or optional accessories before placing ...

Page 4: ...tpump heating 17 4 10 5 Cooling ventilation A Maximum current Fuse rating aM Fuse rating ASE VDE Cable section minimum MAINS Linking pipes Maximum current INTERCONECT Cable section minimum INTERCONECT A A A mm2 A mm2 24 8 25 25 3Core 4 2 6Core 1 5 12 4 25 25 5Core 1 5 2 6Core 1 5 A 11 2 17 4 POWER SUPPLY V PH Hz 13 45 18 75 25 25 3Core 4 2 6Core 1 5 13 94 GC30RCFA GC45RCFX GC30RCC OUTDOOR K30RCF K...

Page 5: ...rs 29 m 5 m 17 grs 290 grs 30 m 6 m 34 grs 348 grs 31 m 7 m 51 grs 406 grs 32 m 8 m 68 grs 464 grs 33 m 9 m 85 grs 522 grs 34 m 10 m 102 grs 580 grs 35 m 11 m 119 grs 638 grs 36 m 12 m 136 grs 696 grs 37 m 13 m 153 grs 754 grs 38 m 14 m 170 grs 812 grs 39 m 15 m 187 grs 870 grs 40 m 16 m 204 grs 928 grs 41 m 17 m 221 grs 986 grs 42 m 18 m 238 grs 1044 grs 43 m 19 m 255 grs 1102 grs 44 m 20 m 272 g...

Page 6: ...0 625 1 2 5 6 7 8 9 Ø 1 2 3 3 4 4 Ø 200 Ø 100 10 10 11 585 5 150 120 140 369 430 118 5 1 False ceiling 2 T shaped rod false ceiling 3 Evaporator 4 Fan 5 Return air grille 6 Electrical box removable 7 Draining of condensates 8 GAS pipe 9 LIQUID pipe 10 Supply air pop prepunched 11 fresh air pop prepunched 510 30 5 30 5 K INST MENU ...

Page 7: ...337 362 380 WIRING CONNECTIONS LIQUID TUBE FLARED SUCTION TUBE FLARED AIR INTAKE AIR OUTLET 357 50 695 340 97 900 706 55 225 293 DIMENSIONS OF OUTDOOR UNIT GC30RCFA 7 K INST MENU ...

Page 8: ... VIEW WIRING CONNECTIONS SUCTION PIPE FLARED LIQUID PIPE FLARED RIGHT VIEW 25 100 DIMENSIONS OF OUTDOOR UNIT GC45RCFX 340 380 WIRING CONNECTIONS 90 50 130 230 290 AIR INTAKE AIR OUTLET 356 5 50 705 100 1255 900 WALL 200 MIN 300 MIN WALL 600 MIN WALL MINIMUM CLEARANCE 800 MIN WALL 500 MIN FROM TOP 15 DIMENSIONS OF OUTDOOR UNIT GC30RCC 8 K INST MENU ...

Page 9: ...0 and multiple Installation of the unit is made easier when using a fork lift truck and the base of the packing by placing the base between the unit and the forks of the truck It is recommended during installation to choose the location of the unit as much as possible in the middle of the room so as to obtain the best distribution of treated air Check that you can remove the discharge grilles and ...

Page 10: ...then the nuts and counter nuts of the threaded rods Finally place the rubber mount Check once more that the unit is in a horizontal position after connection of the condensate drain and the refrigeration pipework DRAINING CONDENSATES To obtain correct condensate drainage the slope downwards should be 1 cm per meter without any bottleneck nor passage upwards Furthermore a trap of at least 50 mm hig...

Page 11: ...their fittings can then be attachedtothecondensatedrainandpowercableswithaclamp INSTALLATION OF REFRIGERANT LINES Drill an 80 mm diameter hole through the wall for the crossing of the lines between the outdoor unit and indoor unit INSTALLATION OF THE OUTDOOR UNIT Minimum clearance to respect in mm Avoid recycling the air even partially between the air inlet and discharge INSTALLATION ON THE FLOOR ...

Page 12: ...the vacuum pump and check that the dial pointer drops to 0 1 MPa 76 cm Hg The pump should remain in operation for at least 15 minutes 4 Before removing the vacuum pump check that the vacuum dial remains stable for five minutes 5 Disconnect the vacuum pump and reclose the service valve 6 Remove the caps from the GAS and LIQUID valves and open them with a socket wrench to release the R22 contained i...

Page 13: ...ld especially ensure an airtight separation between return air and supply air The figure indicates the airtight packings avoiding A the by pass of air B discharge of treated air inside the false ceiling Check after installation that the space between frame and false ceiling is less than 5 mm Latch of the grille Packings AIR INLET AND OUTLET Return Supply air grille Unpack the assembly with care Fi...

Page 14: ...side wall Check that there is no direct contact between the pipework and the wall FIXING Check that the indoor and outdoor units are firmly fixed Install the elements previouly removed MAINTENANCE Before servicing switch the power supply OFF RENEWAL OF AIR Lateral openings allow to install separate ducts for fresh air from outside and supply air towards an adjoining room Remove the anti condensati...

Page 15: ...control unit cable Pull the polystyrene tray out as straight as possible toward the bottom Unscrew the central fan attaching screw Remove the fan Disconnect the motor wires marking on the wires and the connector Remove the four motor support screws Replace the motor Reconnect the new motor carefully checking the marking on each wire Install the motor support Install the fan Install the polystyrene...

Page 16: ... POWER SUPPLY K30RCF POWER SUPPLY 240 V 50 Hz GC30RCFA GC30RCC K45RCF GC45RCFX POWER SUPPLY 3N 415 V 1 6 K INST MENU ...

Page 17: ...oolant to increase Checkthatthesurfaceofthealuminiumfinsoftheheatexchanger is not damaged by impacts or scratches and clean with an appropriate tool if necessary ELECTRICAL SECTION ELECTRICAL SECTION ELECTRICAL SECTION ELECTRICAL SECTION ELECTRICAL SECTION Check that the main power supply cable is not damaged or altered in such a way as to affect the insulation Check that the interconnecting cable...

Page 18: ...NECTION TO THE INDOOR LIQUID VALVE DURING INSTALLATION AS THE ABOVE ILLUSTRATION WARNING WITHOUT THIS KIT THE UNIT WILL NOT OPERATE PROPERLY IN THE HEATING MODE FOR CONNECTION TO INDOOR UNIT RESTRICTOR KIT INSTALLATION RESTRICTOR KIT INSTALLATION SUCTION VALVE RESTRICTOR LIQUID VALVE 1 8 K INST MENU ...

Page 19: ...ffices on the parkSuite 27 8 Greenhill Road Wayville SA 5034 TEL 08 8372 7866 FAX 08 8372 7816 PERTH Suite 23 350 Cambridge St Wembley WA 6014 TEL 08 9284 0800 FAX 08 9284 0600 NEWCASTLE Suite 3 19 Darby Street Newcastle NSW 2300 TEL 02 4940 4652 FAX 02 4940 4653 NEW ZEALAND 517A Rosebank Road Avondale Auckland NZ TEL 09 820 0333 FAX 09 820 0332 www airwell com au NZ Tech Support Freecall TEL 0800...

Reviews: