12-7
SM
J
EDE 11--A.1A.1 GBGB
CONTROL SYSTEMS
12.6
Dry Mode
I
f RAT>SPT, the unit starts drying operation. Indoor fan, outdoor fan and compressor will operate and
the indoor fan will run at low speed.
If SPT-2
≤RAT≤SPT, the unit will keep running in the original mode.
If RAT<SPT-2, the compressor will stop running and the outdoor fan will delay 30 seconds to stop.
While the indoor fan will run at low speed.
In this mode, the Reverse Valve will be OFF and the temperature setting range is 16~30.
12.7
Louver Control
After power on, the up and down swing louver will automatically open and
then close completely.
In heating mode, if the swing function is not set, the up and down louver
will rotate to maximum in clockwise direction. Then it will rotate to position
D. Under other states, the upper and lower air deflector will rotate to level
L.
If the swing function is set when starting the unit, the louver will swing
between Position L and D. there are 7 states for louver: in position L, A, B,
C, D, and swing between L and D, stop in any place between Position L
and position D. When the unit is turned off, the air deflector will stay in
position 0.
The swing is available only when the swing function is set and the indoor fan is running.
The louver swing can also be set between L and B, between A and C, between B and D.
Summary of Contents for ELECTRA AWAU-VDDE009-H11
Page 14: ...OUTLINE DIMENSION SM JEDE 1 A 1 GB 4 2 4 2 Outdoor VDDE009 4 3 Outdoor VDDE012...
Page 15: ...4 3 SM JEDE 1 A 1 GB SOUND LEVEL CHARACTERISTICS 4 4 Outdoor VDDE018 4 5 Outdoor VDDE024...
Page 21: ...SM JEDE 1 A 1 GB 9 1 WIRING DIAGRAM 9 WIRING DIAGRAM 9 1 JEDE009 JEDE012 9 2 JEDE018...
Page 22: ...WIRING DIAGRAM SM JEDE 1 A 1 GB 9 2 9 3 JEDE024 9 4 VDDE009...
Page 23: ...9 3 SM JEDE 1 A 1 GB WIRING DIAGRAM 9 5 VDDE012 9 6 VDDE018 VDDE024...
Page 47: ...14 2 SM JEDE 1 A 1 GB CHARACTERISTICS OF SENSOR 14 1 3 CTT CTT R T Chart...
Page 51: ...EXPLODED VIEW SPARE PART LIST 15 4 SM JEDE 1 A 1 GB 15 4 Exploded view of indoor unit JEDE018...
Page 58: ...SM JEDE 1 A 1 GB 15 11 SERVICING 15 11 Exploded view of outdoor unit YDDE018...
Page 60: ...SM JEDE 1 A 1 GB 15 13 SERVICING 15 13 Exploded view of outdoor unit VDDE024...
Page 63: ...SM JEDE 1 A 1 GB a APENDIX APPENDIX...
Page 64: ...SM HDDE 1 A 1 GB 15 15 SERVICE MANUAL JEDE009 012 018 024...