RATING CONDITIONS
INTRODUCTION
2-3
SM
JE
DE 1-A.1 GB
OUTDOO
R
INDOOR
Model Indoor Unit
AWAU-
JE
DE018-N11
Model Outdoor Unit
AWAU-
V
DDE018-H11
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Heating
Average
Warmer
Capacity
(1)
kW
5,3 (1,2-6,3)
5,6 (1,1-6,4)
Pdesign
kW
5,3
4,8
5,3
SEER / SCOP
(2)
W/W
5,4
3,8
4,6
Energy efficiency class
A
A
A++
Annual energy consumption
kWh
345
1768
1611
Tbiv
o
C
N/A
-7
??
Tol
o
C
N/A
-15
-10
Power supply
V/Ph/Hz
220-240V/Single/50Hz
Circuit breaker rating
A
25
Fan type & quantity
Cross flow fan x1
Fan speeds
H/M/L
RPM
1350/1100/950/800
1400/1200/1050/900
Air flow
(3)
H/M/L
m3/hr
800/680/560/460
800/680/560/460
External static
pressure
Min-Max
Pa
0
Sound power level
(4)
H/M/L
dB(A)
60/55/51/46
Sound pressure level
(5)
H/M/L
dB(A)
49/44/40/35
Moisture removal
l/hr
1,8
Condensate drain tube I.D
mm
16
Dimensions
WxHxD
mm
865x305x215
Weight
kg
12
Package dimensions
WxHxD
mm
948x310x383
Packaged weight
kg
15
Units per pallet
units
18 units per pallet
Stacking height
units
6 levels
Refrigerant control
Capillary
Compressor type, model
Twin Rotary DC Inverter
Fan type & quantity
Axial x 1
Fan speeds
H/L
RPM
750
Air flow
H/L
m3/hr
3200
Sound power level
(4)
H/L
dB(A)
65
Sound pressure level
(5)
H/L
dB(A)
55
Dimensions
WxHxD
mm
955x700x396
Weight
kg
46
Package dimensions
WxHxD
mm
1029x750x458
Packaged weight
kg
50
Units per pallet
Units
6 units per pallet
Stacking height
units
2 levels
Refrigerant type
R410A
Refrigerant charge (standard connecting
tubing length)
kg(5m)
1.3
Additional charge per 1 meter
gr / 1m
5m<L<25m 20g/m
Liquid line
In.(mm)
1/4"(6.35)
Connections
between units
Suction line
In.(mm)
1/2"(12.7)
Max.tubing length
m.
Max.25
Max.height difference
m.
Max.10
Operation control type
Remote control
Heating elements
kW
Others
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units).
(2) SEER / SCOP calculation accordance with EN14825.
Summary of Contents for ELECTRA AWAU-VDDE009-H11
Page 14: ...OUTLINE DIMENSION SM JEDE 1 A 1 GB 4 2 4 2 Outdoor VDDE009 4 3 Outdoor VDDE012...
Page 15: ...4 3 SM JEDE 1 A 1 GB SOUND LEVEL CHARACTERISTICS 4 4 Outdoor VDDE018 4 5 Outdoor VDDE024...
Page 21: ...SM JEDE 1 A 1 GB 9 1 WIRING DIAGRAM 9 WIRING DIAGRAM 9 1 JEDE009 JEDE012 9 2 JEDE018...
Page 22: ...WIRING DIAGRAM SM JEDE 1 A 1 GB 9 2 9 3 JEDE024 9 4 VDDE009...
Page 23: ...9 3 SM JEDE 1 A 1 GB WIRING DIAGRAM 9 5 VDDE012 9 6 VDDE018 VDDE024...
Page 47: ...14 2 SM JEDE 1 A 1 GB CHARACTERISTICS OF SENSOR 14 1 3 CTT CTT R T Chart...
Page 51: ...EXPLODED VIEW SPARE PART LIST 15 4 SM JEDE 1 A 1 GB 15 4 Exploded view of indoor unit JEDE018...
Page 58: ...SM JEDE 1 A 1 GB 15 11 SERVICING 15 11 Exploded view of outdoor unit YDDE018...
Page 60: ...SM JEDE 1 A 1 GB 15 13 SERVICING 15 13 Exploded view of outdoor unit VDDE024...
Page 63: ...SM JEDE 1 A 1 GB a APENDIX APPENDIX...
Page 64: ...SM HDDE 1 A 1 GB 15 15 SERVICE MANUAL JEDE009 012 018 024...