![Airwell DLS 43 DCI Service Manual Download Page 15](http://html1.mh-extra.com/html/airwell/dls-43-dci/dls-43-dci_service-manual_2880116015.webp)
3-1
RATING CONDITIONS
SM DLSDCI 3-A.1 GB
3. RATING
CONDITIONS
Standard conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and
EN 14511.
Cooling:
Indoor: 27
o
C DB 19
o
C WB
Outdoor: 35
o
C DB
Heating:
Indoor: 20
o
C DB
Outdoor: 7
o
C DB 6
o
C WB
3.1 Operating
Limits
Indoor
Outdoor
Cooling
Upper limit
32
o
C DB 23
o
C WB
46
o
C DB
Lower limit
21
o
C DB 15
o
C WB
-10
o
C DB
Heating
Upper limit
27
o
C DB
24
o
C DB 18
o
C WB
Lower limit
10
o
C DB
-15
o
C DB -16
o
C WB
Voltage
1PH
198 - 264 VAC
3PH
323 - 440 VAC
Summary of Contents for DLS 43 DCI
Page 62: ...SM DLSDCI 3 A 2 GB 9 2 WIRING DIAGRAMS 9 3 Indoor Unit DLS 43 DCI...
Page 117: ...12 4 CONTROL SYSTEM SM DLSDCI 3 A 1 GB 12 11 7 Segment Legend 7 7 segments lege end...
Page 154: ...SM DLSD CONTRO DCI 3 A 2 OL SYSTEM M 15 2...
Page 155: ...SM DLSD CONTRO DCI 3 A 2 OL SYSTEM M 15 3...
Page 156: ...SM DLSD CONTRO DCI 3 A 2 OL SYSTEM M 15 4...