9-12
WIRING DIAGRAMS
SM DLSDCI 3-A.1 GB
9.15
3PH UNITS POWER SUPPLY TO OUTDOOR UNIT
7
6
1
4
8
COMM2
COMM1
NC
L
N
L1
N
L
N
COMM2
COMM1
5
2
3
L3 L2
NC
N
L3
L2
L1
10
9
1. Indoor
Unit
2.
Power Supply Cable
3.
Main Power Breaker
4. Outdoor
Unit
5.
Interconnecting cable (2x0.75mm
2
)**
6.
Power Interconnecting Cable (3x1.5mm
2
)
7.
Wireless remote Control
8. Display
Unit
9. Display
Connector
10.
Power Breaker (*by installer)
11. Control
Cable**
12.
Sensor Wire with connector
13. Room
Temperature
Sensor
* The power breaker must be of type that disconnects all poles with 3 mm contact
opening.
** Use shielded cable and connect the shield to earth point