Window WDF-60Hz 5 Version - 0
There is risk of fire or explosion.
Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.
They may burn of explode.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do
not use the remote of the batteries have leaked.
The chemical in batteries could cause burns or other health hazards.
2. Specification.
Model
AWWR-WDF009-C12
AWWR-WDF012-C12
Characteristics
Units
Cooling
Cooling
Capacity
(1)
kW
2,7
3,5
EER
W/W
3,1
3,1
Power supply
V/Ph/Hz
220-240V/Single/60Hz
220-240V/Single/60Hz
Circuit breaker rating
A
10
10
INDO
O
R
Fan type & quantity
Cross flow fan x1
Cross flow fan x1
Fan speeds
H/M/L
RPM
970/870/780
970/870/780
Air flow
(3)
H/M/L
m3/hr
530/470/400
500/450/381
External static pressure
Min-Max
Pa
0
0
Sound pressure level
(5)
H/M/L
dB(A)
54/51/47
54/51/46
Moisture removal
l/hr
1
1,2
Condensate drain tube
mm
OD15
OD15
O
UTDO
O
R
Refrigerant control
Capillary
Capillary
Compressor type, model
Rotary
Rotary
Sound pressure level
(5)
H/M/L
dB(A)
63/60/57
64/61/57
Dimensions
WxHxD
mm
600x380x560
600x380x560
Weight
kg
35
36
Package dimensions
WxHxD
mm
685x430x620
685x430x620
Packaged weight
kg
40
41
Stacking height
units
5 levels
5 levels
Refrigerant type
R410A
R410A
Refrigerant charge
kg
0,5
0,53
Operation control type
Remote control
Remote control
Summary of Contents for AWWR-WDF009-C12
Page 18: ...Window F4 16 Version 0 9 Operation characteristics...
Page 28: ...Window F4 26 Version 0 12 Exploded view and part list Exploded View AWWR WDF009 C12...
Page 30: ...Window F4 28 Version 0 Exploded View AWWR WDF012 C12...
Page 32: ...Window F4 30 Version 0 Exploded view AWWR WDF018 C12...
Page 34: ...Window F4 32 Version 0 Exploded view AWWR WDF024 C12...
Page 36: ...Window F4 34 Version 0 SERVICE MANUAL Window WDF 60Hz Series...