Window WDF-60Hz 15 Version - 0
condensation water on the condenser coil.
If the splashing sound annoys you, you can provide an outside drain by using the
following procedure, which may however cause a small loss of performance.
1. Slide out the chassis from the cabinet.
2. Remove the rubber plug from the body base plate.
3. Install the drain pan to the corner of the cabinet with 2 screws.
4. Connect the drain hose to the outlet on the drain pan bottom.
5. Slide the chassis into its original place in the cabinet.
8.4 How to install.
1)
Remove the sticker from the front panel.
2)
Put the unit into the installation hole.
When installing the unit, it should be
slanted down to the back to avoid the
enlargement of noise or vibration.(Slant
between 6-10mm.)
The installation place should be strong
enough to avoid the enlargement of noise
or vibration.
3)
Fill up sews in the cabinet with sponge or
foam.
Use iron support
The installation hole should be strong
enough to support the air conditioner. If
it cannot, iron support has to be used
outdoors.
Iron support should be fixed on the
building.
Use sunshade board
Air conditioner should avoid anything to
be dropped into it and avoid direct
sunshine. If there is no cover on it, you
should contact the seller for installing the
sunshade board. When installing the
sunshade board, don’t let it block the air
at the side grille.
Summary of Contents for AWWR-WDF009-C12
Page 18: ...Window F4 16 Version 0 9 Operation characteristics...
Page 28: ...Window F4 26 Version 0 12 Exploded view and part list Exploded View AWWR WDF009 C12...
Page 30: ...Window F4 28 Version 0 Exploded View AWWR WDF012 C12...
Page 32: ...Window F4 30 Version 0 Exploded view AWWR WDF018 C12...
Page 34: ...Window F4 32 Version 0 Exploded view AWWR WDF024 C12...
Page 36: ...Window F4 34 Version 0 SERVICE MANUAL Window WDF 60Hz Series...