Window WDF-60Hz 23 Version - 0
The compressor operates run-stop frequently.
Check whether the airflow passage is blocked.
Check whether the fan motor doesn't work.
Check whether capacitor of compressor work normally.
Check whether the relay of compressor on PCB works normally.
Replace the PCB.
Check whether the capillary is blocked.
Replace the capillary.
Replace the compressor.
No
No
No
No
No
No
No
Summary of Contents for AWWR-WDF009-C12
Page 18: ...Window F4 16 Version 0 9 Operation characteristics...
Page 28: ...Window F4 26 Version 0 12 Exploded view and part list Exploded View AWWR WDF009 C12...
Page 30: ...Window F4 28 Version 0 Exploded View AWWR WDF012 C12...
Page 32: ...Window F4 30 Version 0 Exploded view AWWR WDF018 C12...
Page 34: ...Window F4 32 Version 0 Exploded view AWWR WDF024 C12...
Page 36: ...Window F4 34 Version 0 SERVICE MANUAL Window WDF 60Hz Series...