background image

7

Water flow sound

Cracking sound

Terrible smell in
outlet air

Flashing operating
indicator

Awaiting indication

Sound in
shutdown indoor
unit or white
steam or cold air

Clicking sound
when switching the
air condition on

Start or stop working
automatically

Failure to work

Bad cooling &
heating effects

Symptoms

Reasons

Water flow sound can be heard when starting operation, during
operation or immediately after stopping operation. When it starts
to work for 2-3 minutes, the sound may become louder, which is
the flowing sound of refrigerant or the draining sound of condensed
water.
During operation, the air conditioner may make the cracking
sound, which is caused from the temperature changes or the
slight dilation of heat exchanger.

The terrible smell, caused from walls, carpet, furniture, clothing,
cigarette and cosmetics, attaches on the conditioner.

When switching it on again after power failure, turn on the manual
power switch and the operating indicator flashes.

It displays the awaiting indication as it fails to perform refrigerating
operation while other indoor units are in heating operation. When
the operator set it to the refrigerating or heating mode and the
operation is opposite to the setting, it displays the awaiting indication.

To prevent oil and refrigerant from blocking the shutdown indoor
units, refrigerant flows in the short time and make the sounds
of refrigerant flowing. Otherwise, when other indoor units performs
heating operation, white steam may occur; during refrigerating
operation, cold air may appear.

When the conditioner is powered on, the sound is made due
to the resetting of the expansion valve.

Check if it is in the state of Timer-ON and Timer-OFF.

Check if there is a power failure.
Check if the manual power switch is turned off.
Check if the supply fuse and breaker are disconnected.
Check if the protective unit is working.
Check  if  refrigerating  and  heating  functions  are  selected
simultaneously with the awaiting indication on line control.

Check if air intake port and air outlet port of outdoor units are
blocked.
Check if the door and windows are open.
Check if the filtering screen of air cleaner is blocked with sludge
or dust.
Check if the setting of wind quantity is at low wind.
Check if the setting of operation is at the Fan Operation state.
Check if the temperature setting is proper.

When other abnormal conditions occur.

Under the following circumstances, immediately stop the operation, disconnect the manual supply
switch and contact the after-service personnel.

When buttons are inflexible actuated;

When it cannot still be operated after removing the operation of protective unit;

When fuse and breaker have been burnt over and over;
When there are foreign objects and water in the refrigerator;

Fault Checkup

Please check the following when consigning repair service:

Summary of Contents for AWSI-CBV005-N11

Page 1: ...1 AWSI CBV016 N11 AWSI CCV018 N11 AWSI CCV024 N11 AWSI CCV030 N11 AWSI CCV038 N11 AWSI CCV042 N11 AWSI CCV048 N11 No 0150510086 Please read this manual carefully before using Keep this operation manual for future reference Indoor Unit Operation Installation Manual ...

Page 2: ...WSI CCV030 N11 CCV030 AWSI CCV024 N11 CCV024 AWSI CBV009 N11 CBV009 AWSI CBV012 N11 CBV012 AWSI CBV016 N11 CBV016 AWSI CCV018 N11 CCV018 AWSI CBV007 N11 CBV007 AWSI CCV038 N11 CCV038 AWSI CCV042 N11 CCV042 AWSI CBV005 N11 CBV005 Product Features Hanging style installation to save space Automatic display of faults Function of central control optional from our company The air conditioner is provided...

Page 3: ...1 Indoor Units electrical cabinet wind deflector regulate wind direction with remote controller inlet grid air cleaner in inlet grid CBV005 016 CCV018 048 Parts and Functions ...

Page 4: ...he electrical cabinet lipping the wiring Improper installation might cause such accidents as heating or fire accidents While placing or reinstalling the air conditioner except the specific refrigerant R410A don t let the air go into the refrigeration cycle system The air in the refrigeration cycle system might lead to the cracking or personal injuries due to abnormal high pressure of the refrigera...

Page 5: ...ely 2 10 min During defrosting the fan of the indoor unit runs at a low speed or stops while that of the outdoor unit stops running Do not use water heater or like next to the indoor unit and the wired controller Water power leakage or short circuit may happen if the steam generating apparatus is working next to machine Use the fuse with proper capacity Metal wires and copper wires etc may cause f...

Page 6: ...ir conditioner operates in the environment with too much dust clean the air conditioner more times generally once every two weeks CBV005 016 CCV018 048 1 Remove the air inlet grid as shown in the figure press down the two locks on the grid as shown in Fig 1 to move it close to the nearby grid gently lift it 45 degree as shown in Fig 2 and then remove the air inlet grid Maintenance 2 Dismantle the ...

Page 7: ...e grid after determining that the grid is abutting upon the bottom of the panel frame CBV005 016 CCV018 048 Cleaning Air Cleaner Cleaning Clean the air cleaner with the dust collector or water to remove dusts For too much dust use the fan or directly spray the special cookware detergent on the air inlet grid and then clean it with water after 10 minutes A remove dust with dust collector B for too ...

Page 8: ... on to the power After cleaning the air cleaner must be mounted After Operating Season There is no blockage in inlet port and outlet port of outdoor and indoor units The ground line and the wiring are in the proper state If abnormal condition occurs consult the after service personnel Cleaning Wind Deflector Do not wipe the wind deflector with water forcibly to avoid the floss falling off Attentio...

Page 9: ...door units refrigerant flows in the short time and make the sounds of refrigerant flowing Otherwise when other indoor units performs heating operation white steam may occur during refrigerating operation cold air may appear When the conditioner is powered on the sound is made due to the resetting of the expansion valve Check if it is in the state of Timer ON and Timer OFF Check if there is a power...

Page 10: ...ocal installation point of our company Indoor units should be installed in places with the environment of even circulation of cool and warm blows The following places should be avoided 1 Select the following places to install indoor units 1 Indoor unit must be used inside of room not outdoor side or some places with high humidity like laundry 2 where there is enough room for the machine above the ...

Page 11: ...th the ceiling before suspending the unit set refrigerant pipe drainpipe connection line in the room lead wire of line control to the locations of piping and wiring Confirm the size of the indoor unit and fix it according to the requirements in the manual Installation Procedures gap between studs 535mm indoor unit 570mm ceiling 650mm decorated board 700mm holder decorated board ceiling The ceiling...

Page 12: ...ling water level polythene tube 1 Install the indoor unit temporarily attach the hoisting foot to hoisting stud Make sure that nuts and washers should be used at two ends of the foot to secure the foot 2 For the size of the ceiling hole please refer to the schematic drawing at the previous page After finishing the installation of the ceiling 3 Adjust the unit to the proper installation location 4 ...

Page 13: ...or remote control the lamp will not flash when wired controller is used Requirements The drainpipe of the indoor unit should be heat insulated Heat insulation should be treated for the connection with the indoor unit Improper heat insulation may cause condensing The drainpipe with the down gradient of over 1 100 can t be in the S shape or abnormal sound can be caused The horizon length of the drai...

Page 14: ...g Drainpipe The drainpipe can be lifted 360mm When the down gradient of the drainpipe can t be ensured after upright lifting the drainpipe is in the down slope Confirming Drainage The drainage should be confirmed during the test run to make sure that there is leakage at the connection The confirmation of drainage should be also performed during the installation in the winter season Fill water from...

Page 15: ...ier after heading it through the ring at the end of the lead and then tighten it 2 Connecting straight terminals The connection methods for the circular terminals are shown as follows loosen the screw before putting the line terminal into the terminal tier tighten the screw and confirm it has been clamped by pulling the line gently 3 Pressing connecting line After connecting line is completed pres...

Page 16: ...ter The power line of indoor units should be arranged according to the installation instruction of indoor units The electrical wiring should be out of contact with the high temperature sections of tubing as to avoid melting the insulating layer of cables which may cause accidents After connected to the terminal tier the tubing should be curved into be a U type elbow and fastened with the pressing ...

Page 17: ...ways between line control and indoor units A One line control controls multiple units i e 2 16 indoor units as shown in the above figure 1 5 indoor units The indoor unit 5 is the line controlled main unit and others are the ine controlled sub units The remoter control and the main unit directly connected to the indoor unit of line control are connected via three lines with polarity Other indoor un...

Page 18: ...be connected together with the shielded lay at the side of signal lines of outdoor units grounded at one point It is not permissible if the whole length of signal line exceeds 1000m The wiring for the power line of indoor unit the wiring between indoor and outdoor units as well as the wiring between indoor units 10 2 20 20 20 A 30 mA 0 1S or below 10 and 15 3 5 25 30 30 A 30 mA 0 1S or below 15 an...

Page 19: ...ontrol address the other corresponding address can change automatically meeting as follows Central control address equals to physical address plus 0 or 64 Dip switch setting In the following table 1 is ON 0 is OFF SW01 is used for indoor unit group control address setting and capacity selection CN44 CN42 CN43 are used for indoor unit type selection CN41 is used for addressing by wired controller S...

Page 20: ...iff correction valve in AUTO mode SW07_1 SW07_2 Tdiff correction valve in AUTO mode 1 SW07_3 26 lock 4 0 0 1 1 Normally without 26 degree lock function defaulted 26 degree lock function is availble In cooling mode though set temp is below 26 degree count as 26 degree In heating mode though set temp exceeds 20 degree count as 20 degree Inlet air temp Tai correction valve Tcomp2 eeprom Tai correctio...

Page 21: ... Normal mode TES is unavailable default TES is available 1 0 1 0 1 1 0 0 1 0 1 Run at Mid speed when Hi Speed is selected Quiet running mode Indoor and outdoor 90 meters drop selection Reserved Indoor installation height selection Twin energy source J1 J2 J3 J4 J5 J6 J7 J8 Function switches Note ON indicates short circuit OFF indicates disconnection Remarks Betewwn SW7 and SW8 one and only one mus...

Page 22: ...ing line is fastened check if the connectors for tubing are heat insulated check if the indoor units are positioned Ways of Test Run Do ask the installation personnel to make a test run Take he testing procedures according to the manual and check if the temperature regulator works properly When the machine fails to start due to the room temperature the following procedures can be taken to do the c...

Page 23: ...n valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground water and find their way into the food chain When moving to disassemble and re install the air conditioning please contact your dealer for technical support In the composition material of air conditioning the content of l...

Page 24: ......

Reviews: