MAINTENANCE

Technical specifications 

Please read data plate to obtain the technical data listed below.

Power supply voltage

Maximum absorbed power

Maximum absorbed current

Amount of refrigerant gas

Casing protection rating

Note:

The product is compliant with the ERP (Energy Related Products) European directive.
It includes Commission delegated Regulation (EU) No 2016/2281, also known as Ecodesign Lot 21
Performances referred to the maximum speed fan (Max.)
1) Cooling: inlet air temperature 27°C w.b./19°C d.b.; in/out water temperature 30°C/35°C
2) Heating: inlet air temperature 20°C; in/out water temperature 10°C/7°C (well source)
3) Water flow rate measured in cooling at maximum speed fan (Max.)

Internal ambient temp.

Water inlet temp.

Maximum operating temperature in cooling mode

45° C

Minimum operating temperature in cooling mode

7° C

Maximum operating temperatures in heating mode

40° C

Minimum operating temperatures in heating mode

7° C

Operating limits 

Technical specifications
Size

XDO 09

XDO  012

Cooling

Cooling capacity

1

kW

2.53

3.56

Total power input

1

kW

0.384

0.762

EER

1

-

6.58

4.67

Heating

Heating capacity

2

kW

2.27

3,26

Total power input

2

kW

0.710

1.089

COP

2

-

3.20

3.00

Compressor

Type of copressor

-

Inverter driven

Inverter driven

N° of compressor

-

1

1

Refrigerant gas

R-410A

R-410A

Refrigerant charge

kg

0.75

0.75

Air handling section fan

Type of fan

-

Centrifugal

Centrifugal

Number of fan

-

1

1

Min. air flow rate

m

3

/h

195

220

Med. air flow rate

m

3

/h

250

310

Max. air flow rate

m

3

/h

310

410

Boost air flow rate

m

3

/h

385

435

Water side exchanger

Type of exchanger

-

Coaxial

Coaxial

Water flow rate

3

l/s

0.139

0.206

Water fittings

Eurokonus M 3/4"

Eurokonus M 3/4"

Power supply

Standard power supply

V/ph/Hz

230/1/50

230/1/50

Noise Levels

Sound power level 

dB(A)

52

57

Summary of Contents for AW-XDO009-H11

Page 1: ...XDO Direct expansion console water source DC Inverter technology Silent heat pump EN Installation manual...

Page 2: ...ronic equipment 2011 65 EC RoHS2 Waste electrical and electronic equipment 2012 19 EC WEEE Energy consumption indication on the labels of energy related products 2010 30 EU ErP Directive 2009 125 EC a...

Page 3: ...parts 2 Installation Installation method Choosing the position of the unit Assembling the unit Condensation drain preparation Mounting the appliance on the bracket Hydraulic connection Electrical con...

Page 4: ...l Technical Assistance Service Repairs or maintenance must be performed by the Technical Assistance Service or by qualified personnel in accordance with this manual Do not modify or tamper with the ap...

Page 5: ...n a high or low position Everything that is required for installation assembly template support brackets except for the drill of course is contained in the packaging Remote control and on board touch...

Page 6: ...attery Installation manual Handling The unit is packed singularly in a cardboard box Boxes can either be carried singularly by hand by two operators or loaded on a forklift truck for a maximum of thre...

Page 7: ...s Air outlet flaps Touch screen display Front panel Water input Eurokonus M 3 4 Water output Eurokonus M 3 4 Internal air intake grille Air Filter Anti lifting bracket Room air probe Power supply term...

Page 8: ...avoid malfunctions or dangerous situations the location of the unit must meet the following requisites Respect the minimum distances indicated in the diagram The wall on which you intend to anchor the...

Page 9: ...w density place a bracket if necessary on the outside that can support the appliance safely The manufacturer cannot be held responsible for any underestimation of the structural consistency of the anc...

Page 10: ...t is necessary to add a siphon before placing the pipe into the main drain This siphon must be placed at least 300 mm under the mouth of the appliance If the line flows into a container e g a tank do...

Page 11: ...les sand rust slag or any foreign bodies that may damage the system It is advisable to provide a by pass in the system in order to be able to wash the exchanger without having to disconnect the applia...

Page 12: ...ces to be integrated for safety KEY TO SYMBOLS 1 Temperature probe 2 Anti vibration joint 3 Exhaust valve 4 Mesh filter 5 6 Shut off valve 7 Safety valve 8 Expansion tank for pressure surges 9 Flow sw...

Page 13: ...characteristics of water During the initial start up the specialised technician must measure the system water reference values using the special test kits System water reference values pH Electrical c...

Page 14: ...ith suitable protections against overloads and or short circuits using a 10 Amp Time delay fuse or other equivalent devices is recommended To prevent any risk of electrocution always disconnect the ma...

Page 15: ...to a free non live contact the appliance is put is stand by and CP appears on the display Using this contact it is possible to connect an external device that inhibits the functioning of the applianc...

Page 16: ...the lower hole Remove the upper grill Remove the two plastic side panels by moving them up Unscrew the fixing screws Remove the front panel Place the bottom cover and fix it with the supplied screws o...

Page 17: ...he night button for 10 seconds ds disabled or En enabled will appear on the display Open CP contact Touch screen display key lock Hotel function Display indications Cause E1 Faulty room temperature RT...

Page 18: ...lop or where there are humidity and temperature conditions that exceed the maximum levels reported on the installation manual Clean the air filter regularly as described in the specific paragraph Befo...

Page 19: ...o start up the appliance after a period of inactivity NB before performing any operation take care with the hot and or sharp surfaces of the metal The filter is located in the top part of the applianc...

Page 20: ...ncreased for example a door or a window has been left open or an appliance has been installed in the room which generates a lot of heat Try to reduce the heating and cooling load of the room following...

Page 21: ...cooling mode 45 C Minimum operating temperature in cooling mode 7 C Maximum operating temperatures in heating mode 40 C Minimum operating temperatures in heating mode 7 C Operating limits Technical sp...

Page 22: ...22...

Page 23: ...e Vertr glichkeit compatibilidad electromagn tica 2009 125 UE Ecodesign co conception Progettazione ecocompatibile Ecodesign Ecodise o 2011 65 UE RoHs Unit manufactured and tested according to the fol...

Page 24: ...AIRWELL RESIDENTIAL 3 Avenue du Centre Les Quadrants B timent A 78280 GUYANCOURT France Tel 33 0 1 76 21 82 00 www airwell pro fr contact airwell res com...

Reviews: