![Airwell AW-FWDB018-N91 Service Manual Download Page 41](http://html1.mh-extra.com/html/airwell/aw-fwdb018-n91/aw-fwdb018-n91_service-manual_2879982041.webp)
FWDB Low temperature floor ceiling-Technical Manual R32-50Hz
9 Troubleshooting
9.1 18K outdoor unit
Error code display
Error
code
Description
Error
code
Description
E01
Communication fault between IDU
and ODU
P0C
Current protection
E02
Zero cross detection fault of IDU
P1x
Bus voltage protection
E03
stall fault of indoor fan
P21
Low temperature dehumidication fault
E04
T2B (indoor coil outlet temp.) sensor
fault
P22
High and low temp. protection of
evaporator
E08
Mode conflict
P23
High temp. protection of condenser
E09
ODU EEPROM error
P24
High and low temp. protection of
environment
E0E
IDU EEPROM error
P25
High
discharge
temperature
of
compressor
E11
IDU T1 (room temperature) sensor
fault
P28
Abnormal discharge in commodity
inspection mode
(compressor reversal)
E12
IDU T2 (indoor coil middle temp.)
sensor fault
P29
T3 abnormal in commodity inspection
heating mode
(System
exception,
4-way
valve
disconnected)
E13
ODU T3 (outdoor coil outlet temp.)
sensor fault
P30
High pressure protection
E14
ODU T4 (ambient temp.) sensor fault P31
Low pressure protection
E15
ODU discharge temp. sensor fault
H1x
Compressor fault
E16
Module temp. sensor fault
H3x
PFC fault
E17
Suction temp. sensor fault
L01
Lower frequency because of voltage
limit
E18
TZA sensor fault
L02
Lower frequency because of high or low
temp. limit of evaporator
E19
TZB sensor fault
L03
Lower frequency because of high temp.
limit of condenser
E2x
Fan motor fault
L05
Lower frequency because of high
discharge temp. of compressor
L06
Lower frequency because of module
temperature limit
L0C
Lower frequency because of current
limit
39
Summary of Contents for AW-FWDB018-N91
Page 15: ...FWDB Low temperature floor ceiling Technical Manual R32 50Hz 13 4 Service Space ...
Page 18: ...FWDB Low temperature floor ceiling Technical Manual R32 50Hz 16 6 2 AW FWDB024 N91 ...
Page 33: ...FWDB Low temperature floor ceiling Technical Manual R32 50Hz 4 2 AW YMDB024 H91 31 ...
Page 39: ...FWDB Low temperature floor ceiling Technical Manual R32 50Hz 8 2 AW YMDB024 H91 37 ...
Page 57: ...FWDB Low temperature floor ceiling Technical Manual R32 50Hz 55 ...