Page 44
compensation mixing
1) Press the ENTER key to move the cursor to OFFSET, then press the
INC/+ or DEC/- keys to adjust the desired OFFSET value.
By setting the OFFSET value to 100, the Dial Knob (Auxiliary Channel 3) can be set so that no mixing occurs when the Dial
Knob is turned all the way to the left, but full mixing will occur when the Dial Knob is turned all the way to the right. Set the
H percentage value to 50% (or other desired value), set the L value to 0%, then set the OFFSET value to 100.
C-MIX C-MIX1 OFFSET setting range is -150 to 150. The default setting
is 0.
0
MAX
Dial
Knob
H: 50%
L: 0%
MASTER
SLA
VE
H
B
L value is set to 0% since no operation
occurs on the L side with an OFFSET.
Since no operation occurs beyond 100 when the MASTER is set to AUX1, this can be set to 100.
ACT/INH Setting
1) To use the C-MIX1 function, it must be Activated. Press the ENTER
key to move the cursor to C-MIX, then press the INC/+ or DEC/- keys to
either ACT (Activate) or INH (Inhibit) the C-MIX1 function.
The C-MIX1 ACT/INH setting can be assigned to any Push-Button
switch using the Key Assign function. See page 50 for more
information. By using this function, switching C-MIX1 'ON' or 'OFF' can be
selected during model operation.
[C-MIX2] COMPENSATION MIXING 2
1) Press the Function key to move the cursor to [C-MIX2] in the C-MIX
Programming Window. The cursor will default to ST1.
2) Use the same techniques that you used to adjust the values for C-MIX1
to adjust the desired values for C-MIX2.
The C-MIX2 ACT/INH setting can be assigned to any Push-Button switch using the Key Assign function. See page 50 for
more information. By using this function, switching C-MIX1 'ON' or 'OFF' can be selected during model operation.
Both C-MIX1 and C-MIX2 can be Active at the same time.