Instruction manual - Purifier

K7 770 HEPA

4

TRANSPORT AND STORAGE

OPERATING INSTRUCTIONS

Store  in  a  dry  place  and  protected  from  the  elements.  If  the  packaging  is  open,  cover  the  purifier

 

to protect it from dust� Do not step on or place heavy loads on it to avoid damage to the material� 

Storage temperature between -20⁰C and + 40⁰C.

When transporting the material you must ensure that it is not damaged by the forklift 

(possible penetration of the fork in the packaging)� Observe the instructions on the packaging�

To put the device into operation, just connect it to a voltage of 230Vx1 50 / 60Hz, as indicated in the elec-

trical diagram on the next page. This device works with a constant flow rate that the user does not need 

to  configure. The  fan  itself  regulates  itself  to  maintain  a  flow  rate  of  300m³  /  h  until  the  filters  are  dirty.

 

When the filters are no longer able to hold particles, a red light comes on. This indicates that dirty filters 

should be replaced with clean ones. Furthermore, the team cannot guarantee that the flow (and consequently 

the renewals / hour) will be maintained until clean filters are installed.

ATTENTION! Heavy object. 

Do not stand under the suspended load during transport or assembly.

Power supply

Fixings

The K7 770 A HEPA air purifier has a 3 meter, 3-way cable (line, neutral and ground) that must be connected 

to a 230Vx1 50 / 60Hz power outlet�

A  switch  can  be  connected  between  the  equipment  and  the  power  outlet.  In  this  way  you  can

 

disconnect the equipment in a simple way.

The equipment has several external attachment points. The anchor must be sized according to the device 

weights indicated on the technical data page (see pages 6-7)� The installation can be carried out with threa-

ded rods, tensioners or other supports (see section “accessories”)�

Autoregulation

This device provides a constant air flow of 300 m³ / h. As the filters get dirty, the equipment itself regulates 

itself to maintain said flow.

The equipment is configured at the factory, it only needs to be powered with 230Vx1 50 / 60Hz current.

Summary of Contents for K7 770 HEPA

Page 1: ...tallation Give this manual to the end user SAFETY WARNING SYMBOLS Attention danger warning of security Danger Danger of injury Attention Do not get under the load High weight Important information INS...

Page 2: ...D STORAGE 4 OPERATING INSTRUCTIONS 4 Power supply 4 Autoregulation 4 Fixings 4 ELECTRICAL SCHEMES 5 DATASHEET 6 DATASHEET 7 MAINTENANCE INSTRUCTIONS 8 REPAIRS AND REPLACEMENTS 9 ACCESSORIES 12 FAULTS...

Page 3: ...ol a specific manual is attached that must be used for its installation and operation It is necessary to remove the service grill to connect the equipment The electrical connection is made in an IP bo...

Page 4: ...dicates that dirty filters should be replaced with clean ones Furthermore the team cannot guarantee that the flow and consequently the renewals hour will be maintained until clean filters are installe...

Page 5: ...TRICOS DE UNIDADES DE VENTILACI N de WIRING DIAGRAMS OF VENTILATI N UNITS Page of K7 770 HEPA Caudal constante Regulaci n fija PE N L PE N L Amarillo verde Azul Negro Q 3 230Vx1 50Hz Caja de conexione...

Page 6: ...res bacteria viruses and fine particles PM10 PM2 5 and PM1 Self supporting galvanized steel frame prepared for recessed installation in false cei lings Easy access log panel for filter replacement Suc...

Page 7: ...HEPA 7 DATASHEET Operation infographic Maintenance Air purified outlet Air inlet Indicator Filter change Service panel Service door for filters Threaded knob to adjust the position of the filters insi...

Page 8: ...deadline An annual cleaning of the discharge area should be performed Cleaning of the unit casing should be done with a damp cloth and conventional detergent Do not use corrosive caustic or acid conta...

Page 9: ...ese instructions Before carrying out any repairs you must Notify staff and indicate that work is in progress Disconnect the current and protect the thermal magnet so that no one can actuate it by acci...

Page 10: ...filters under normal operating conditions is Prefilter G4 500 hours Compact filter F7 1000 hours Absolut filter H14 3500 hours It is recommended to check the condition of the filters every six months...

Page 11: ...the current make sure that there is no voltage and the turbine does not rotate Open the service panel as indicated in the previous section The new fan is installed following the above procedure in re...

Page 12: ...manual Purifier K7 770 HEPA 12 ACCESSORIES Supports and shock absorbers according to installation see references in attached document Standard cable clamp Silentblock in angle Silentblock rod damper R...

Page 13: ...hes the equipment and if not check the power cables 3 1 If the equipment has voltage but the fan does not rotate check if there is 5 5V in continuous between the yellow and black cables 3 2 In case th...

Page 14: ...e s directiva s Low Voltage Directive 2014 35 UE Directiva Baja Tensi n 2014 35 UE Electromagnetic Compatibility Directive 2014 30 UE Directiva Compatibilidad Electromagn tica 2014 30 UE Restriction C...

Page 15: ...istics flow rate technical data of the fans It is essential to have this number to provide possible spa re parts or technical information on the purifier in question In case of detecting errors or amb...

Page 16: ...Pla de la Bruguera E 08211 Castellar del Vall s Barcelona Spain 34 93 715 99 88 airtecnics airtecnics com www airtecnics com WELDOM10025 R0 17 09 21 We reserve the right to change design and specifica...

Reviews: