Instruction manual - Purifier
K7 770 HEPA
11
Fan replacement
Service panel opening
The service panel covers the inside of the unit� Through it you can access the fans and the connection
box��
Before replacing the fan, it is necessary to notify that it is working, disconnect the current, make sure that
there is no voltage and the turbine does not rotate�
Open the service panel as indicated in the previous section�
The new fan is installed following the above procedure in reverse order, making sure that the connection in
the IP box is correct (follow instructions on page 4)�
2- Remove the screws
1- Remove the screws
1- Disconnect the fan power ca-
bles inside the connection box
0- Service panel
3- Remove fan
2- Gently remove the
service panel down