background image

En-6

TROUBLESHOOTING

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

Symptom

Doesn’t operate at all:

Poor Cooling
(or *Heating)
performance:

See Page

CHECK ONCE

MORE

Items to check

Has there been a power failure?

Has a fuse blown out, or a circuit breaker been tripped?

Is the main power switch set to the OFF position?

Is the timer operating?

Is the air filter dirty?

Are the air conditioner’s intake grille or outlet port blocked?

Did you adjust the room temperature settings (thermostat) cor-
rectly?

Is there a window or door open?

In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)

In the case of Cooling operation, are there heating apparatus and
computers inside the room, or are there too many people in the
room?

If the problem persists after performing these checks, or if you notice burning smells, stop operation immediately, turn off the
electrical breaker, and consult with authorized service personnel.

OPERATING TIPS

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

*Heating Performance

This air conditioner operates on the heat-pump principle,
absorbing heat from outdoor air and transferring that heat
indoors. As a result, the operating performance is reduced
as outdoor air temperature drops. If you feel that insuffi-
cient heating performance is being produced, we recom-
mend you use this air conditioner in conjunction with
another kind of heating appliance.

Heat-pump air conditioners heat your entire room by
recirculating air throughout the room, with the result that
some time may be required after first starting the air con-
ditioner until the room is heated.

*Cooling/Heating Priority (HEAT PUMP MODEL only)

If another indoor unit in the same system is already oper-
ating in the cooling mode or dry mode, heating mode
settings cannot be performed. (Operation in the cooling
or dry mode will continue.)

If another indoor unit in the same system is already oper-
ating in the heating mode, cooling mode or dry mode
settings cannot be performed. (Operation in the cooling
or dry mode will continue.)

Operation and Performance

*Microcomputer-controlled Automatic Defrosting

When using the Heating mode under conditions of low out-
door air temperature high humidity, frost may form on the
outdoor unit, resulting in reduced operating performance.

In order to prevent this kind of reduced performance, this
unit is equipped with a Microcomputer-controlled Automatic
Defrosting function. If frost forms, the air conditioner will
temporarily stop, and the defrosting circuit will operate
briefly (for about 4 to 15 minutes).

During Automatic Defrosting operation, the OPERATION in-
dicator lamp (red) will flash.

Oil Recovery Operation

Periodically, the oil recovery operation is performed in or-
der to return compressor oil to the outdoor unit.  Operation
is stopped during this oil recovery operation.  During oil re-
covery operation, the OPERATION indicator lamp (red) will
flash.

Low Ambient Cooling

When the outdoor temperature drops, the outdoor unit’s fans
may switch to Low Speed, or one of the fans may stop inter-
mittently.

Summary of Contents for AU 54TF

Page 1: ...ED OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ MANUAL DE INSTRUÇÕES P N9369314018 Indoor Unit AU 20TF AU 25TF AU 30TF AU 36TF AU 45TF AU 54TF Français Español Italiano EλληvIkά Português Русский TM English Deutsch ...

Page 2: ...ndle with care Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow When restarting after a long period of disuse in the winter do Turn the power switch on at least 12 hours before starting the unit Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals...

Page 3: ...ker is installed during the electrical installation Electrical Breaker Fig 5 0 A A 0 Fig 3 Fig 1 Indoor Unit 1 Air Filter 2 Air Intake Grille 3 Air Flow Direction Flaps 4 Indicator Lamps Fig 2 5 SWING Indicator Lamp orange 6 TIMER Indicator Lamp green 7 OPERATION Indicator Lamp red 8 Operating Control Panel Fig 3 9 MANUAL AUTO Button ...

Page 4: ...in unit control panel To stop operation press the MANUAL AUTO button once again When the air conditioner is operated with the controls on the Main unit it will operate under the same mode as the AUTO mode selected on the re mote control unit However the Heat pump model will follow the operating mode of the other indoor unit The fan speed selected will be AUTO and the thermostat setting will be 23 ...

Page 5: ... pull the fil ter out Before cleaning the unit be sure to stop the unit and disconnect the power supply Turn off the electrical breaker A fan operates at high speed inside the unit and personal injury could result CAUTION When reinstalling the filter be sure that the hooks at A and B engage correctly into place 4 Clean the air filters Remove the dust from the air filters by vacuuming or washing th...

Page 6: ...emperature changes During Heating operation a sizzling sound may be heard occa sional This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This result...

Page 7: ...d of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Cooling Heating Priority HEAT PUMP MODEL only If another indoor unit in the same system is already oper ating in the cooling mode or dry mode heating mode settings cannot be...

Page 8: ...te to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Heating Dehumidifying and air circulation of rooms in ordinary dwellings SPECIFICATIONS Temperature and Humidity ...

Reviews: