background image

En-1

CONTENTS

SAFETY PRECAUTIONS ....................................... 1

NAME OF PARTS ................................................... 2

MANUAL AUTO OPERATION ............................... 3

CLEANING AND CARE .......................................... 4

TROUBLESHOOTING ............................................ 5

OPERATING TIPS ................................................... 6

SPECIFICATIONS ................................................... 7

Do not attempt to install this air conditioner by yourself.

This unit contains no user-serviceable parts. Always consult authorized service per-
sonnel for repairs.

When moving, consult authorized service personnel for disconnection and installa-
tion of the unit.

Do not become over-exposed to cold air by staying in the direct path of the airflow of
the air conditioner for extended periods of time.

Do not insert fingers or objects into the outlet port or intake grilles.

Do not start and stop air conditioner operation by turning off the electrical breaker
and so on.

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn
off the electrical breaker, and consult authorized service personnel.

Provide occasional ventilation during use.

Do not direct air flow at fireplaces or heating apparatus.

Do not climb on, or place objects on, the air conditioner.

Do not hang objects from the indoor unit.

Do not set flower vases or water containers on top of  air conditioners.

Do not expose the air conditioner directly to water.

Do not operate the air conditioner with wet hands.

Turn off power source when not using the unit for extended periods.

Always turn off the electrical breaker whenever cleaning the air conditioner or the air
filter.

Connection valves become hot during Heating; handle with care.

Check the condition of the installation stand for damage.

Do not place animals or plants in the direct path of the air flow.

When restarting after a long period of disuse in the winter, do:
Turn the power switch on at least 12 hours before starting the unit.

Do not drink the water drained from the air conditioner.

Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.

Do not apply any heavy pressure to radiator fins.

Operate only with air filters installed.

Do not block or cover the intake grille and outlet port.

Ensure that any electronic equipment is at least one metre away from either the in-
door or outdoor units.

Avoid installing the air conditioner near a fireplace or other heating apparatus.

When installing the indoor and outdoor unit, take precautions to prevent access to infants.

Do not use inflammable gases near the air conditioner.

CAUTION!

SAFETY PRECAUTIONS

Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.

The instructions in this section all relate to safety; be sure to maintain save operating conditions.

“DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:

DANGER!

WARNING!

CAUTION!

This mark indicates procedures which, if improperly performed, are most likely to
result in the death of or serious injury to the user or service personnel.

This mark indicates procedures which, if improperly performed, might lead to the
death or serious injury of the user.

This mark indicates procedures which, if improperly performed, might possibly result
in personal harm to the user, or damage to property.

DANGER!

Summary of Contents for AU 54TF

Page 1: ...ED OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ MANUAL DE INSTRUÇÕES P N9369314018 Indoor Unit AU 20TF AU 25TF AU 30TF AU 36TF AU 45TF AU 54TF Français Español Italiano EλληvIkά Português Русский TM English Deutsch ...

Page 2: ...ndle with care Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow When restarting after a long period of disuse in the winter do Turn the power switch on at least 12 hours before starting the unit Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals...

Page 3: ...ker is installed during the electrical installation Electrical Breaker Fig 5 0 A A 0 Fig 3 Fig 1 Indoor Unit 1 Air Filter 2 Air Intake Grille 3 Air Flow Direction Flaps 4 Indicator Lamps Fig 2 5 SWING Indicator Lamp orange 6 TIMER Indicator Lamp green 7 OPERATION Indicator Lamp red 8 Operating Control Panel Fig 3 9 MANUAL AUTO Button ...

Page 4: ...in unit control panel To stop operation press the MANUAL AUTO button once again When the air conditioner is operated with the controls on the Main unit it will operate under the same mode as the AUTO mode selected on the re mote control unit However the Heat pump model will follow the operating mode of the other indoor unit The fan speed selected will be AUTO and the thermostat setting will be 23 ...

Page 5: ... pull the fil ter out Before cleaning the unit be sure to stop the unit and disconnect the power supply Turn off the electrical breaker A fan operates at high speed inside the unit and personal injury could result CAUTION When reinstalling the filter be sure that the hooks at A and B engage correctly into place 4 Clean the air filters Remove the dust from the air filters by vacuuming or washing th...

Page 6: ...emperature changes During Heating operation a sizzling sound may be heard occa sional This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This result...

Page 7: ...d of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Cooling Heating Priority HEAT PUMP MODEL only If another indoor unit in the same system is already oper ating in the cooling mode or dry mode heating mode settings cannot be...

Page 8: ...te to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Heating Dehumidifying and air circulation of rooms in ordinary dwellings SPECIFICATIONS Temperature and Humidity ...

Reviews: