TROUBLESHOOTING

The following conditions are not breakdowns or operation failures.

Symptom

Problem

See page

Doesn’t operate immediately:

If the unit is stopped and then immediately started again, the compressor will not operate for about 

 

3 minutes, in order to prevent fuse blowouts.

Whenever the electrical breaker is turned off then on again, the protection circuit will operate for 

 

about 3 minutes, preventing unit operation during that period.

Air

fl

 ow is weak or stops:

When Heating operation is started, indoor unit’s fan may temporarily stop, to allow internal parts to 

 

warm up.

During Heating operation, if the room temperature rises above the thermostat setting, the outdoor 

 

unit will stop, and the indoor unit’s fan will stop. If you wish to warm the room further, set the ther-
mostat for a higher setting.

During oil recovery operation, the air 

fl

 ow may stop for approximately 10 minutes.

 

2

During Heating operation, the unit will temporarily stop operation (between 4 and 15 minutes) as 

 

the Automatic Defrosting mode operates.

2

The fan may operate at low speed during Dry operation or when the unit is monitoring the room’s 

 

temperature.

In the monitor AUTO operation, the fan will operate at low speed.

 

Flashing lamps:
(Limited to only when receiver 
unit is connected)

The Operation indicator lamp 
(green) 

fl

 ashes:

An oil recovery operation is being performed.

2

The Operation indicator lamp 
(green) 

fl

 ashes:

An automatic defrosting operation is being performed.

2

The Operation indicator lamp 
(green) and Timer indicator lamp 
(orange) are 

fl

 ashing alternately: 

It has recovered from a power outage.

The Operation indicator lamp 
(green) and Timer indicator lamp 
(orange) are 

fl

 ashing simultane-

ously: 

It is operating in trial operation mode.
Ask a manager as there may be maintenance being conducted.

The Operation indicator lamp 
(green) lights up and the Timer 
indicator lamp (orange) 

fl

 ashes:

This is the standby state.

2

Noise is heard:

In the following conditions there are sounds of water 

fl

 owing from the indoor unit and the operation 

 

sound becomes loud. These are the sounds of the 

fl

 owing of refrigerant.

 When operation starts 
When oil recovery operation 

fi

 nishes 

When automatic defrosting operation 

fi

 nishes

During operation, a slight squeaking sound may be heard. This is the result of minute expansion 

 

and contraction of the panel due to temperature changes.

During Heating operation, a sizzling sound may be heard occasionally. This sound is produced by 

 

the Automatic Defrosting operation.

2

Smells:

Some smell may be emitted from the indoor unit. This smell is the result of room smells (furniture, 

 

tobacco, etc.) which have been taken into the air conditioner.

Fog comes out of the indoor unit:

During Cooling operation, a thin mist may be seen emitted from the indoor unit. This results from 

 

the sudden Cooling of room air by the air emitted from the air conditioner, resulting in condensation 
and misting.

Steam comes out of the indoor 
unit:

During Heating operation, the outdoor unit’s fan may stop, and steam may be seen rising from the 

 

unit. This is due to the Automatic Defrosting operation.

2

Water is produced from the 
outdoor unit:

During Heating operation, water may be produced from the outdoor unit due to the Automatic 

 

Defrosting operation.

9374343096-02_OM.indb   4

9374343096-02_OM.indb   4

2011-12-21   16:13:06

2011-12-21   16:13:06

Summary of Contents for ARUL12RLAV

Page 1: ...ep this manual for future reference MANUAL DE INSTRU ES UNIDADE INTERNA Tipo de duto Guarde este manual para refer ncia futura MANUAL DE FUNCIONAMIENTO UNIDAD INTERIOR Tipo de ducto Conserve este manu...

Page 2: ...e indoor unit Do not place anything below the indoor unit that should not get wet Always turn off the electrical breaker whenever cleaning the air condi tioner or the air filter Do not expose the air...

Page 3: ...and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend yo...

Page 4: ...r volatile agents like benzene or thinner If dirt is allowed to accumulate on the air filter air flow will be reduced lowering operating efficiency and increasing noise During periods of normal use th...

Page 5: ...lamp orange are flashing alternately It has recovered from a power outage The Operation indicator lamp green and Timer indicator lamp orange are flashing simultane ously It is operating in trial opera...

Page 6: ...a window allowing bright sunlight to enter Close the curtains In the case of Cooling operation are there heating apparatus and computers inside the room or are there too many people in the room Is the...

Page 7: ...4 0 15 600 4 6 20 000 5 9 SOUND PRESSURE LEVEL HIGH dB A 28 29 30 34 34 MED dB A 25 26 27 32 32 LOW dB A 22 24 24 28 28 DIMENSIONS WEIGHT HEIGHT in mm 7 25 32 198 7 25 32 198 WIDTH in mm 27 9 16 700...

Page 8: ......

Reviews: