605-0001-801 FlexNET Link Products
Basic interface settings
The process of editing the basic interface settings is described below. Remember to click the OK
button to apply the changes you make.
Interface status
This pair of radio buttons shows whether the selected interface is currently enabled. To
enable the interface, click on the Enabled radio button. To disable the interface, click on
the Disabled button. Click the OK button to apply the change.
Editing existing IP addresses
The current IP addresses of the selected interface are listed below the basic interface
settings, in the Edit Addresses section of the configuration screen.
To modify an IP address click in the IP Address and/or Subnet Mask fields. Edit the IP
address/subnet mask, and click the OK button.
To delete an IP address click the Delete checkbox beside the IP address(es) you wish to
delete. Click the OK button to remove the checked address(es).
Adding a new IP address
Assign a new IP address to the selected interface by using the Add Address fields at the
bottom of the configuration screen. Enter a new IP address and subnet mask in the
respective text fields of the selected interface, and click the Add button.
Note: Remember to click on the OK button to apply your changes, and click
Commit Settings to permanently accept the new configuration.
Changing bridge settings
Click on the NETWORKING>bridge link in the configuration menu to open the configuration
page for the bridge interfaces.
The process of editing the basic interface settings (interface label and status) is exactly as
described for Ethernet interfaces in Section Basic interface settings, on page 18. Interface
settings specific to the bridge interface are described here (see Figure 11 on page 19).
The ASN-700/800 should be configured so that the first Ethernet port (Ethernet 1) is used to
connect the base station towards the Internet or an Airspan ControlNET Server.
Transparent bridging with Ethernet tunnel
A pair of link units can be used as a transparent bridge with Ethernet tunneling option. Both
ends of the radio link must have the same tunnel setting. The bridge configuration shows
option (Activate tunnel) to turn on tunneling for the radio interface. By default the tunnel is
on. When bridging the AP/Master end of a link only, disable the tunnel for the radio in the
bridge. The tunnel setting has no effect when bridge is not enabled.
18