![Airspan AirHarmony-4400 Installation Manual Download Page 30](http://html.mh-extra.com/html/airspan/airharmony-4400/airharmony-4400_installation-manual_2879150030.webp)
AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186
Airspan Commercial and Internal Use
24
3.2.6
Environmental
AirHarmony-4400 meets the following environmental requirements:
GR-63 Storage and Transportation
ETSI EN 300-019-1-4 Operational (non-weather protected equipment)
ETSI EN 300-019-1-1 Storage (weather protected, non-temperature controlled locations)
ETSI EN 300-019-1-2 Transportation
Table 11: AirHarmony-4400 Environment Compliance
Type
Details
Standard Compliance
Operating temperature
-40°C to 55°C / -40°F to 131°F
ETSI 300 019 1-4
Operating humidity
5% - 100% non-condensing
ETSI 300 019 1-4
Storage temperature
-40°C to 70°C
N/A
Storage humidity
5% - 100% non-condensing
ETSI 300 019 1-4
Rain and dust ingress
protection
IP66
N/A
Operational altitude
70-106 kPa as well as:
From -60m to 1800m @ 40
C
From 1800m to 4400m @ 30
C
ETSI 300 019 1-4
Solar radiation
1120 W/m
2
ETSI 300 019 1-4