13
UVHEALTH BIO2000 Installation Manual
7.0 TROUBLESHOOTING GUIDE
If the germicidal UV lamp is not operating (when looking
through the view port):
1. Check to be sure there is correct voltage to the unit and
the ballast is set for the correct voltage.
2. Be sure the lamp connector is fastened securely.
3. Check for loose electrical connections.
4. Test with new lamp and if lamp still does not light,
replace ballast.
7.1 CLEAN-UP OF BROKEN LAMPS
(see warnings in Section 3.0 of this manual)
UV lamps contain a small amount of mercury, like a
typical fluorescent lamp. DO NOT touch any of the
mercury with your bare hands.
1. While wearing disposable, non-absorbent protective
gloves, carefully pick up the large pieces of glass with
your hands.
2. Vacuum the entire area with a standard household
vacuum cleaner ensuring the removal of all lamp
material.
3. Dispose of the pieces of glass, the vacuum cleaner bag,
and the disposable gloves in a sealed garbage bag.
4. Check with your local waste management authority for
local disposal or recycling requirements.
5. Wash hands. Remove and wash clothes for added
safety measures.
8.0 TECHNICAL SPECIFICATIONS
Description
Value
UV-C Germicidal Lamp
50 watts UV-C
Length in Duct
451 mm
UVHealth BIO2000 PCO TiO2
Semiconductor
2.26 m
2
Weight
1.63 kg
Adjustable Voltage
120 or 230 volts
Lamp Life Efficiency Output
Up to 2 years
Average Static Pressure Drop
4.98 pa
Application air flow range for
the UVHealth BIO2000
up to 1000 L/s (17.6 kW)
9.0 REPLACEMENT PARTS LIST
Replacement Part
Number
Part Description
BIO2000PCO
BIO 2000 Honeycomb PCO
105mm x 448mm
BIO2000CARB
BIO 2000 Carbon Filter
BIO2000BLST
BIO 2000 230V Replacement
Ballast Assembly
BIO2000LAMP
BIO 2000 425mm (17.5”)
Replacement Lamp
For replacement parts, contact your air conditioning
specialist installer or maintenance provider.
10.0 WARRANTY
Our goods come with guarantees that cannot be excluded
under the Australian Consumer Law.
You are entitled to a replacement or refund for a major
failure and compensation for any other reasonably
foreseeable loss or damage.
You are also entitled to have the goods repaired or replaced
if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
AirSmart Pty Ltd provides a 1 year parts only warranty for
faulty or defective goods. For warranty information about
this product, visit www.uvhealth.com.au.
If your UVHealth BIO2000 unit is not operating correctly,
please contact the supplier or air conditioning specialist.