background image

Please take a few minutes to read over this manual and its accompanying documents.

Before power-up of  the unit, inspect it for any damage that may have been sustained during shipping.  

DO NOT USE DAMAGED EQUIPMENT. If  you suspect this unit was damaged during shipping, contact AirScape 
technical support by phone at 1.866.448.4187, or email at 

[email protected]

.

THEORY OF OPERATION

AirScape’s HEPA Tower was designed to greatly minimize exposure to airborne pathogens, pollen and 

dust by quietly filtering the air in the room. 
The design intent was to create a mobile HEPA filter unit that would quietly filter any room, work space, 

office space, conference room or waiting room to minimize the airborne transmission of viruses, viral 
particles, and removal of pollen, fungal spores and dust, that can accumulate in indoor air. 
This stand alone unit recirculates and filters the air (HEPA=99.95%) in the space it is being used.
It works by pulling in contaminated air from low in the room and pushing the air up high thus creating an

airflow pattern [high to low] that reduces human exposure to contaminants.

PURCHASE OPTIONS (not included)

A wireless remote is an available accessory option for AirScape’s HEPA Tower. The wireless remote is 

NOT included as part of this fan’s standard control package. The yellow manual included with these 
accessories provides specific instructions for the installation and operation of the remote.

If purchased

, the wireless remote receiver is connected to the fan electrical box at the blue RMT RJ45 

port. If purchased at the time of the purchase of the HEPA Tower, AirScape will install the remote 

receiver in the unit. If purchased after; Installation means removal of  the rear panel, installation of the 
remote receiver and blue Cat5E cable, an operational test and reinstalling the rear panel.

Replacement HEPA Filter and MERV11 Pre-filters  can also be purchased

SAFETY INFORMATION

•  

The HEPA TOWER does NOT remove gasses.

•  The HEPA TOWER is not for use in professional kitchens.

•  Before servicing the Tower, unplug the fan from the wall receptacle 

to reduce the risk of damaging   

   circuit boards,  fire, electrical shock, or injury.

•  

A used HEPA Filter should be treated as “infected” or contaminated and discarded taking 

   precautions. Avoid touching the filter material.

•  Perform periodic checks of  the air flow pattern, physically feel air moving in and out of the HEPA 

  Tower and around the room.

•  When installing a new HEPA Filter avoid touching the filter material as this may damage (create a 

   hole in) the HEPA Filter and thus nullify the HEPA standard.

•  Strapping the unit to the wall using a few Rear Panel (access panel) screws is a good way to create 

   some earthquake protection. (straps not included)

HEPA TOWER Installation and Operation Manual, 0221

©AirScape, Inc., 2021. All Rights Reserved.                                                                                                                 Page 2

Summary of Contents for HEPA TOWER

Page 1: ...particle diameters both less than and greater than 0 3 microns ECM Motor High Efficiency to quietly produce high volume airflow in ten speed steps with optional remote control capable of many room air...

Page 2: ...manual included with these accessories provides specific instructions for the installation and operation of the remote If purchased the wireless remote receiver is connected to the fan electrical box...

Page 3: ...n Micro Droplets Viruses Airborne Organisms Fungal Spores Pollen Dust Magnetic Inlet Grille Filter Frame Screws in Filter Frame to hold HEPA Filter Press Fit Pre Filter Mobile Clean air is supplied hi...

Page 4: ...e speed setting If the Fan was turned on by TIMER UP the timer will be set to one hour and blue LED s will illuminate to indicate the timer setting Press or hold FAN UP to increase the fan s speed to...

Page 5: ...to the entire room and minimizing the airflow dead zone behind the unit You can control where your tower s airflow is directed by adjusting the louvers on the Air Exit Grille on top of the Tower and i...

Page 6: ...esentation penetrates further into the room In this cut view it is clear how much further the 700 CFM curve reaches toward the far walls of the room Dead zones or area s of air stagnation occur in upp...

Page 7: ...ow will disturb the airflow pattern through the room any HVAC operation will temporarily disturb the airflow pattern through the room any standing fan operation will disturb the airflow pattern throug...

Page 8: ...9 4 6 4 3 4 1 3 9 3 7 3 5 3 3 3 2 3 1 2 9 50 7 1 6 4 5 9 5 4 5 0 4 7 4 4 4 1 3 9 3 7 3 5 3 4 3 2 3 1 2 9 2 8 The table is based on 8 foot ceilings and a 940 CFM unit EXCELLENT 12 ACH VERY GOOD 9 12 AC...

Page 9: ...T touch the HEPA Filter Material Slide HEPA Filter into the Tower place the filter frame and secure it with the 4 screws Filter Frame Assembly Mounts by screwing it into the Tower with a Philips head...

Page 10: ...ESS PANEL HEPA Tower Rear Top Access Panel Removed HEPA TOWER Installation and Operation Manual 0221 AirScape Inc 2021 All Rights Reserved Page 10 Controller Fan s Electrical Box Cord Wrap Box removab...

Page 11: ...inside the fan s electrical box DTC Digital Touch Controller Symptom Audible click but Fan does not start Possible causes Wiring issue between Fan Box Board and Fan Suggestion 1 Open Fan s electrical...

Page 12: ...12 Digital Touch Controller Optional Remote Optional Remote Receiver Fan Motor incl Wiring EL 9013 20 foot Power Cord 120VAC 60Hz 1 Phase 15A Connect to dedicated circuit Power Supply 120VAC IN 24VDC...