fastening bolts and replace the V-belt. Worn V-belts should be replaced by new
ones with the same size.
Note: Regular maintenance of your compressor will increase durability and
reliability.
MAINTENANCE TABLE
works
daily
weekly
every
every
250 hours 1000 hours
draining
condensation water
▀
check
oil level
▀
clean
air filter
▀
refresh oil (first
time
after 50 hours)
▀
check V-belt
▀
7.0 POSSIBILIBIES OF FAILURE
1 Compressor does not run at starting pressure:
*
blown fuse
- renew the fuse
*
tank at pressure
- discharge
*
motor broken
- repair/renew
*
defective pressure switch
- repair/renew
* thermal fall out
- reset
2 Repeating thermal failure:
*
blown fuse
- renew fuse
*
loose wire
- repair
*
pressure switch does not releave
- repair/renew valve
air circuit
*
too low voltage
- remove extension cable or use heavier
*
overloading
- reduce loading
3 Compressor keeps blowing off air:
*
defective non-return valve
- repair/renew
4 Too little air production:
*
dirty air filter
- clean/renew filter
*
V-belt too loose
- tighten V-belt