Main battery
The 12 V main battery is mounted on the engine side of the firewall.
Main bus
Refer to the applicable supplement at the end of this manual for aircraft
fitted with a 914 UL engine or 912 iS engine.
When power to the main bus is unavailable / fails the following equipment
becomes non-operational:
1.
Auxiliary (electric) fuel pump (912 ULS).
2.
Flaps.
3.
Autopilot (i.e. the autopilot servos).
4.
Propeller (if applicable).
5.
Radio.
6.
Transponder (if fitted).
7.
Cabin light(s).
8.
Strobe, navigation and taxi lights.
9
EFIS (unless powered by the EFIS battery back-up circuit)
With regard to the above:
1.
The EFIS and related equipment (GEA 24, GSU 25) can be operated via
the EFIS back-up battery circuit, provided that the circuit is switched
on and the EFIS back-up battery contains adequate charge.
2.
The propeller controller (if applicable) and propeller pitch actuator
motor (if applicable) are not powered and the propeller (if applicable)
essentially becomes a fixed pitch propeller at the last pitch setting it
was commanded to (by the propeller controller).