![Airplane Factory Sling-2 Pilot Operating Handbook Download Page 64](http://html1.mh-extra.com/html/airplane-factory/sling-2/sling-2_pilot-operating-handbook_2878758064.webp)
Airplane Factory SLING 2
Pilot Operating Handbook
Page | 3-20
DC-POH-002-X-B-6
Revision : 2.6
3.7.4
Alternator / charge system failure
For aircraft fitted with the 912 iS or 914 UL engine please refer to the
supplement at the end of this manual
Failure of the alternator / charge system will result in the main battery
not being charged. Alternator (914 UL / 912 ULS) failure is evidenced by
the illumination of the (red) alternator charge warning light.
1.
EFIS main switch
- off.
2.
All non-critical electrical equipment
- off.
(navigation, strobe, taxi, landing lights etc.).
3.
Auxiliary fuel pump
- off.
4.
Autopilot
- off.
5. Propeller (if applicable)
- AUTO/CLIMB (or
as desired).
6.
When propeller (if applicable) governs at climb setting - MAN.
7.
Propeller switch (if applicable)
- off.
8.
Set EFIS brightness to minimum.
9.
Restrict / avoid the use of the elevator trim control. Restrict radio
transmission to minimum / only that which is absolutely necessary.
10.
Land as soon as possible.
NOTE
When landing with adequate battery power remaining (to power
both the propeller motor (if applicable) and (if required for 912
ULS) the electric fuel pump(s)) the propeller (if applicable) can
be re-energized and selections made as applicable.
NOTE
The 912 ULS engine operation is independent from the aircraft
main battery (except for start motor operation) / alternator. The
engine will continue running after an alternator failure and / or
with a depleted battery.