WX Series WeatherStation Technical Manual revision 1.000
Proprietary and Confidential
PRELIMINARY - DRAFT
71
_
NMEA 0183 RECEIVED SENTENCE
_
$PAMTC,
ERST
Summary
Reset the user portion of nonvolatile EEPROM to its factory default state.
Syntax
$PAMTC,ERST*hh<CR><LF>
Notes
The following data items are saved in nonvolatile EEPROM within the WX Series
WeatherStation Sensor. For each item, the default value, and the command used
to change the value is shown.
Item
Default value
Changed via command
Azimuth offset
0.0°
$PAMTC,ATTOFF
Pitch offset
0.0°
$PAMTC,ATTOFF
Roll offset
0.0°
$PAMTC,ATTOFF
List of sentences
enabled for transmission
See the description for the
$PAMTC,EN command
$PAMTC,EN
Rates of transmission of
sentences
See the description for the
$PAMTC,EN command
$PAMTC,EN
Allow COG to be used
instead of internal
compass heading in true
wind calculations
Disabled
$PAMTC,OPTION
GPS fix 2D, 3D, or Auto
Auto
$PAMTC,OPTION
Altitude settings
0,1,2
$PAMTC,ALT
Other items related to factory calibration of the sensor are also saved in
EEPROM, but these items are not affected by the $PAMTC,ERST command.
This command performs the same function as the received proprietary NMEA
2000® PGN 126720-130.