4. Troubleshooting
4-3
4.2
Failures of compressor and engine
4.2.1
At start-up, starter rotates slowly
※
1
:
When starter switch is placed at the “START” position, the battery is not normal if B terminal
voltage decreases by 10V.
4.2.2
Receiver tank gauge pressure will not rise up to rated pressure during
unloaded operation
Re-charge and or
supply water/replace.
Check battery cable.
Faulty cable.
Faulty starter motor.
Replace terminal or
assembly.
Repair or replace
assembly.
Normal
Volt: more than 12V
Gravity: more than 1.26
※
1
Faulty
Error in operation
Turn valve to
operation side.
Start side
Operation side
Faulty adjustment of
pressure
Re-adjust pressure
Faulty pressure gauge
Faulty adjustment
Adjustment
Replace it.
Faulty adjustment
Check oil separator for
clogging.
Faulty oil separator.
Differential pressure
too much
Replace it.
Normal
Faulty unloader.
1
Disassemble / clean
or replace
Check battery voltage and
specific gravity.
Faulty
Normal
Battery specific gravity
too low or electrolyte
short.
Check adjustment of
pressure regulator.
Check position of starting
unloader valve.
Change pressure gauge for
replacement one, and
re-adjust pressure gauge.
Adjustment
Discount-Equipment.com
Summary of Contents for PDS185S-6C1
Page 1: ...D i s c o u n t E q u i p m e n t c o m...
Page 19: ...1 Specification 1 15 1 7 Piping Diagram PC08091E D i s c o u n t E q u i p m e n t c o m...
Page 76: ...5 4 PDS185S 6C1 VE PUMP Type PC08047E D i s c o u n t E q u i p m e n t c o m...
Page 77: ...5 5 PDS185S 6C1R IN LINE PUMP Type PC08048E D i s c o u n t E q u i p m e n t c o m...
Page 78: ...5 6 PDS185S 6C1R IN LINE PUMP Type PC08090E D i s c o u n t E q u i p m e n t c o m...