3. Electric System
3-13
(3) Diagnosing when battery charging warning lamp lights
Recharging battery.
Repairing alternator because it is
faulty.
Check charging circuit (connection
between alternator BAT terminal
to battery).
Normal: about 14V
Abnormal
: same voltage as battery
voltage when stopping.
Normal: about 14V
Abnormal
: same voltage as battery
voltage when stopping.
Repairing alternator because it is
faulty.
Normal: about 7.2V
Abnormal
: less than 7.2V
Check charging warning lamp
circuit.
Disconnected check and confirm
waning lamp circuit (P terminal -
controller CN2-17 terminal).
Cable disconnected
Repairing alternator because it is
faulty.
Not cable disconnected
Abnormal
: less than 12V
Normal: 12V
Measure the voltage of
alternator BAT terminal
during operation.
Check the voltage between
alternator P-E terminals at
no load.
Measure battery voltage
during operation.
Measure battery voltage
when engine stops.