7
9
Turn Off
Light Time
4
0~127
After turn on the lighting, setting the delay time to turn off the
lighting when the PIR motion is not detected. 8 seconds per tick,
default tick is 4 (32 seconds).
0 means never send turn off light command.
10
Auto Report
Battery Time
12
0~127
The interval time for auto report the battery level.
0 means turn off auto report battery.
The default value is 12. The tick time can setting by the
configuration No.20.
20
Auto Report
Tick Interval
30
-128~127
The interval time for auto report each tick. Setting this
configuration will effect configuration No.10.
The unit is 1 minute.
Caution1: Setting to 0 means turn off all auto report function.
Caution2: The range is from 0x00~0xFF using hexadecimal
notation.