* NWI
When the device power on, the device will check is it already adding to the network? If doesn't, it will auto start
the NWI mode. The LED will flash in every second and continue 30 seconds. Until timeout or the
device successful to inclusion by controller. The use can presses button once to abort the NWI mode.
* Wake
When the device power on, the device will wake about 20 seconds. In this duration, the controller can
communicate with the device. Normally the device is always sleeping to save the battery energy.
Security Network
The device supports the security function. When the device included with a security controller, the device will
auto switch to the security mode. In the security mode, the follow commands need using Security CC wrapped
to communicate, otherwise it will not response.
Note: A “Security Enabled Z-Wave Controller” must be used in order to fully utilize this function.
COMMAND_CLASS_BATTERY
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_WAKE_UP_V2
Operation Mode
There are two modes “Test” and “Normal”. “Test Mode” is for the user test the sensor function when
installation.“Normal Mode” is for the normal operation.
Operation Mode can be switched by pressing tamper key three times. LED can indicate which mode it is.
Lighting on one second means entering test mode, flashing once means entering normal mode.
When the event triggered, normally the LED won't indicated, unless the battery is in the low level, the LED will
flash once. But in the “Test Mode” the LED also will light ON one second.
When the event triggered, the device will report the messages to the nodes in the group 1. The messages also
include the battery level. The user can switch the report by setting the configuration NO. 7 bit6 (battery).
When the event triggered, the device will emit the signal to turn ON the lighting equipment, those nodes are in
the group 2. And delay a while to turn OFF the lighting equipment. The delay time is setting by the
configuration NO. 9.
The PIR motion re-detected interval, in the “Test Mode” fixed to 6 seconds. In the “Normal Mode”, it
according to the setting of the configuration NO. 8.
Choosing a Suitable Location
•
The recommended mounting height is 160cm
•
Don't let the device facing the window or the sunlight.
•
Don't let the device facing the source of heat. For instance the heater or the air-condition.