2
Function
Description
Add
1. Have Z-Wave
TM
Controller entered inclusion mode.
2. Pressing button once to enter the inclusion mode.
3. After add successful, the device will wake to receive the setting command from Z-Wave
TM
controller about 20 seconds.
Remove
1. Have Z-Wave
TM
Controller entered exclusion mode.
2. Pressing button once to enter the exclusion mode.
Node ID has been excluded.
Reset
Notice: Use this procedure only in the event that the primary controller is lost or
otherwise inoperable.
1. Pressing button for about 5 seconds.
2. IDs are excluded and all settings will reset to factory default.
Association
1. Have Z-Wave
TM
Controller entered association mode.
2. Pressing button one time to enter the association mode.
Note: The device supports 2 groups. The group 1 is for receiving the report message, like
triggered event, temperature, illumination etc. The group 2 is for light control, the device will
send the “Basic Set” command to this group. And each group support 8 nodes maximum.
Failed or success in add/remove the node ID can be viewed from Z-Wave
TM
Controller.
Notice 1: Always RESET a Z-Wave
TM
device before trying to add it to a Z-Wave
TM
network
Notice 2: When the device into NWI mode, the sensor functionality will useless. The NWI mode will timeout
after 30 seconds. You can press the button one time to abort the NWI mode.
Z- Wave
TM
Notification
After the device adding to the network, it will wake-up once per day in default. When it wake-up it will
broadcast the “Wake Up Notification” message to the network, and wake-up 10 seconds for receive the setting
commands.
The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step
is 30 minutes.
If the user wants to wake-up the device immediately, please remove the front cover, and press the button once.
The device will wake-up 10 seconds.
Z-Wave
TM
Message Report
When the PIR motion triggered, the device will report the trigger event and also report the battery status.
In default the device will using Notification Report to represent the trigger event, it can be changed to Sensor
Binary Report by setting the configuration NO. 7 Bit4 to 1.