AirLive SI-102 Manual Download Page 3

 

2

 

 

Function

 

Description

 

Add

 

1. Have Z-Wave

TM

 Controller entered inclusion mode. 

2. Pressing button once to enter the inclusion mode. 

3. After add successful, the device will wake to receive the setting command from Z-Wave

TM 

controller about 20 seconds.

 

Remove

 

1. Have Z-Wave

TM

 Controller entered exclusion mode. 

2. Pressing button once to enter the exclusion mode. 

Node ID has been excluded.

 

Reset

 

Notice: Use this procedure only in the event that the primary controller is lost or 

otherwise inoperable. 

1. Pressing button for about 5 seconds. 

2. IDs are excluded and all settings will reset to factory default.

 

Association

 

1. Have Z-Wave

TM

 Controller entered association mode. 

2. Pressing button one time to enter the association mode. 

Note: The device supports 2 groups. The group 1 is for receiving the report message, like 

triggered event, temperature, illumination etc. The group 2 is for light control, the device will 

send the “Basic Set” command to this group. And each group support 8 nodes maximum.

 

 

Failed or success in add/remove the node ID can be viewed from Z-Wave

TM

 Controller.

 

 

Notice 1: Always RESET a Z-Wave

TM

 device before trying to add it to a Z-Wave

TM

 network 

 

Notice 2: When the device into NWI mode, the sensor functionality will useless. The NWI mode will timeout 

after 30 seconds. You can press the button one time to abort the NWI mode. 

 

Z- Wave

TM

 Notification

 

 

After the device adding to the network, it will wake-up once per day in default. When it wake-up it will 

broadcast the “Wake Up Notification” message to the network, and wake-up 10 seconds for receive the setting 

commands. 

The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step 

is 30 minutes. 

If the user wants to wake-up the device immediately, please remove the front cover, and press the button once. 

The device will wake-up 10 seconds. 

 

Z-Wave

TM

 Message Report

 

 

When the PIR motion triggered, the device will report the trigger event and also report the battery status. 

In default the device will using Notification Report to represent the trigger event, it can be changed to Sensor 

Binary Report by setting the configuration NO. 7 Bit4 to 1. 

Summary of Contents for SI-102

Page 1: ...2 Motion Report 3 Tamper Report 3 Timing Report 3 Power Up Procedure 3 Battery Power Check 3 PIR Warm Up 3 NWI 4 Wake 4 Security Network 4 Operation Mode 4 Choosing a Suitable Location 4 Z Wave Configuration Settings 5 Z Wave Supported Command Class 5 Specifications 8 FCC Interference Statement 9 Warning 9 ...

Page 2: ...aveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Adding to Remove from Z WaveTM Network There are two keys in the device one is t...

Page 3: ... nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout after 30 seconds You can press the button one time to abort the NWI mode Z WaveTM Notification After the device a...

Page 4: ...us Battery level report Every 6 hours report once in default It could be changed by setting the configuration NO 10 Low battery report When the battery level is too low every 30 minutes will report once Notice The configuration NO 10 could be setting to zero to disable the auto report And the configuration NO 20 could change the tick interval the default value is 30 if setting to 1 that means the ...

Page 5: ...and Normal Test Mode is for the user test the sensor function when installation Normal Mode is for the normal operation Operation Mode can be switched by pressing tamper key three times LED can indicate which mode it is Lighting on one second means entering test mode flashing once means entering normal mode When the event triggered normally the LED won t indicated unless the battery is in the low ...

Page 6: ..._POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY No Name Def Valid Description 2 Basic Set Level 1 All Setting the BASIC command value to turn on the light 1 0xFF means turn on the light For dimmer equipment 1 to 100 means the light strength 0 means turn off the light Caution The range is from 0x00 0xFF using hexadecimal notation 3 PIR Sensitivity 80 0 ...

Page 7: ...Enable Note Depends on the Bit4 0 Report Notification CC Type 0x07 Event 0xFE 1 Sensor Binary Report Type 0x0C Value 0x00 1 Bit2 Enable PIR super sensitivity mode 0 Disable 1 Enable 0 Bit3 Reserve 0 Bit4 Notification Type 0 Using Notification Report 1 Using Sensor Binary Report 0 Bit5 Disable Multi CC in auto report 1 Disable 0 Enable 0 Bit6 Disable to report battery state when the device triggere...

Page 8: ...2 0 127 The interval time for auto report the battery level 0 means turn off auto report battery The default value is 12 The tick time can setting by the configuration No 20 20 Auto Report Tick Interval 30 128 127 The interval time for auto report each tick Setting this configuration will effect configuration No 10 The unit is 1 minute Caution1 Setting to 0 means turn off all auto report function ...

Page 9: ...NZ 869 00 MHz RU 865 20 MHz IN 916 00 MHz IL Range Minimum 40 meters indoor 100 meters outdoor line of sight RF Maximum Power 5dBm Operating Temperature 10oC 40oC For indoor use only Specifications subject to change without notice due to continuing product improvement OvisLink Corp http www airlive com TEL 886 2 2218 6888 FAX 886 2 2918 6988 FCC ID ODMSI102 ...

Page 10: ...at to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or mo...

Reviews: