* Motion Report: 

When the PIR motion detected, the device will unsolicited to send the report to the nodes in the group 1. 

 

Notification Report (V4)

 

Notification Type: Home Security (0x07) 

Event: Motion Detection, Unknown Location (0x08)

 

Sensor Binary Report (V2)

 

Sensor Type: Motion (0x0C)   

Sensor Value: 0xFF

 

 

* Tamper Report: 

Both the 2 tamper keys are pressed over 5 seconds. The device will into the alarm state. In that state, if any one 

of the tamper keys be released, the device will unsolicited to send the report to the nodes in the group 1. 

 

Notification Report (V4)

 

Notification Type: Home Security (0x07) 

Event: Tampering. Product covering removed (0x03)

 

Sensor Binary Report (V2)

 

Sensor Type: Tamper (0x08) Sensor Value: 0xFF

 

 

* Timing Report: 

Beside the event triggered could report message, the device also support the timing unsolicited report of the 

status. 

• Battery level report: Every 6 hours report once in default. It could be changed by setting the configuration 

NO. 10. 

• Low battery report: When the battery level is too low, every 30 minutes will report once. 

Notice: The configuration NO. 10 could be setting to zero to disable the auto report. And the configuration NO. 

20 could change the tick interval, the default value is 30, if setting to 1, that means the minimum auto report 

interval will be one minute. And please notice if setting this value to zero, that means disable all of the timing 

report except the low battery detection. 

 

Power Up Procedure 

 

* Battery Power Check 

When the device power up, the device will detect the power level of the battery immediately. If the power level 
is too low, the LED will continue flash about 5 seconds. Please change another new battery.

 

 

* PIR Warm Up 

When the device power on, the PIR need to warm up before the operation. The warm up time about 1 minute, 
the LED will flash in every 2 seconds. After finish the procedure the LED will light ON three times.

 

 

Summary of Contents for SI-102

Page 1: ...2 Motion Report 3 Tamper Report 3 Timing Report 3 Power Up Procedure 3 Battery Power Check 3 PIR Warm Up 3 NWI 4 Wake 4 Security Network 4 Operation Mode 4 Choosing a Suitable Location 4 Z Wave Configuration Settings 5 Z Wave Supported Command Class 5 Specifications 8 FCC Interference Statement 9 Warning 9 ...

Page 2: ...aveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Adding to Remove from Z WaveTM Network There are two keys in the device one is t...

Page 3: ... nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout after 30 seconds You can press the button one time to abort the NWI mode Z WaveTM Notification After the device a...

Page 4: ...us Battery level report Every 6 hours report once in default It could be changed by setting the configuration NO 10 Low battery report When the battery level is too low every 30 minutes will report once Notice The configuration NO 10 could be setting to zero to disable the auto report And the configuration NO 20 could change the tick interval the default value is 30 if setting to 1 that means the ...

Page 5: ...and Normal Test Mode is for the user test the sensor function when installation Normal Mode is for the normal operation Operation Mode can be switched by pressing tamper key three times LED can indicate which mode it is Lighting on one second means entering test mode flashing once means entering normal mode When the event triggered normally the LED won t indicated unless the battery is in the low ...

Page 6: ..._POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY No Name Def Valid Description 2 Basic Set Level 1 All Setting the BASIC command value to turn on the light 1 0xFF means turn on the light For dimmer equipment 1 to 100 means the light strength 0 means turn off the light Caution The range is from 0x00 0xFF using hexadecimal notation 3 PIR Sensitivity 80 0 ...

Page 7: ...Enable Note Depends on the Bit4 0 Report Notification CC Type 0x07 Event 0xFE 1 Sensor Binary Report Type 0x0C Value 0x00 1 Bit2 Enable PIR super sensitivity mode 0 Disable 1 Enable 0 Bit3 Reserve 0 Bit4 Notification Type 0 Using Notification Report 1 Using Sensor Binary Report 0 Bit5 Disable Multi CC in auto report 1 Disable 0 Enable 0 Bit6 Disable to report battery state when the device triggere...

Page 8: ...2 0 127 The interval time for auto report the battery level 0 means turn off auto report battery The default value is 12 The tick time can setting by the configuration No 20 20 Auto Report Tick Interval 30 128 127 The interval time for auto report each tick Setting this configuration will effect configuration No 10 The unit is 1 minute Caution1 Setting to 0 means turn off all auto report function ...

Page 9: ...NZ 869 00 MHz RU 865 20 MHz IN 916 00 MHz IL Range Minimum 40 meters indoor 100 meters outdoor line of sight RF Maximum Power 5dBm Operating Temperature 10oC 40oC For indoor use only Specifications subject to change without notice due to continuing product improvement OvisLink Corp http www airlive com TEL 886 2 2218 6888 FAX 886 2 2918 6988 FCC ID ODMSI102 ...

Page 10: ...at to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or mo...

Reviews: