Maintenance
12
3A1186F
Servicing the Inlet Valve
1.
Un-thread and remove suction nut from fluid pump
body.
2.
Remove suction seat, O-ring, suction ball and suc-
tion retainer.
3.
Clean all parts and inspect them for wear or dam-
age, replacing parts as needed.
4.
Clean inside of the fluid pump body.
5.
Reassemble lower suction valve assembly by plac-
ing the suction seat, O-ring, suction ball and suction
ball guide in the suction nut and screw onto fluid
pump body.