Last Update: 30/01/2017
RL600 Sst
–600 bar – 60 MPa gun
Technical manual :
E 102
Gun suitable for use with pumps up to 600 bar
– 60 MPa rated pressure.
TECHNICAL SPECIFICATIONS MAGNETIC MICROSWITCH WITH REED BULB
Rated voltage:
220 V
Commutable voltage max :
10 VA
Cable length :
2000 mm
Wire:
2 x 0,25mm
2
Room temperature:
100°C
Type of action:
1C
Current max:
0.5 A
P/N
RATED
PRESSURE
bar - MPa
PERMISSIBLE
PRESSURE
bar - MPa
MAX FLOW
RATE
I/min
(1) MAX
TEMPERATURE
°C
INLET
OUTLET
WEIGHT
gr
30.5800.00
600 - 60
660 - 66
60
100
G3/8F-F
1005
*30.5820.00
600 - 60
660 - 66
60
100
G3/8F-F
1020
(1) Attention ! ! !
The work limit of the magnetic microswitch with REED bulb attached to the gun must be
maximum:
48 volt ac-cc
(2)
The gun has been designed for continuous use, at a water temperature of 60°C (140°F). It can resist at the max
temperature of 100°C (210°F) for short periods only, as, when the gun shuts off, the heater continues to transmit the heat
to the water, thus increasing both temperature and pressure up to high, dangerous values.
Using the gun at a water temperature higher than 60°C involves for the operator the use of adequate safety devices,
such as gloves, etc.
Attention ! ! !
In order to prevent the risk of INSTABILITY of the gun due to pressure spikes, CHECK (fig. 3) the use of safety
devices (SHOULDER SUPPORT) in the CHART enclosed, in function of the parameters of Pressure / Flow Rate..
. Instruction manual, maintenance, installation, spare parts.
For a correct utilization, follow the directions of this manual.
Re-print them on the Use and Maintenance booklet of the machine.
n. 12.9102.00
Ed. 04/2002
30.5800.00
RL600 Sst
30.5820.00
RL600 Sst with microswitch
-
Assembly on tubes equipped with G3/8” couplings
-
Entirely made of stainless steel
-
Ergonomic construction
-
The trigger opens up with minimum effort
-
Microswitch version with REED bulb (*)
-
Highly resistant Reed switch
-
Protection degree
IPX3
-
Protection class
III
-
Magnetically controlled by the movement of the trigger
-
In compliance with
norms